97654438 E
Page 35
EP006089
Host-to-LF 6602 Daisy Chain Cable Connections
A terminator must always be installed on the vacant connector of the last SCSI device in the SCSI bus.
The SCSI bus must always be terminated externally on the rear panel of an LF 6600 when an LF 6602 is
the last SCSI device on the bus.
NOTE
You must first determine the type of termination your host system
requires (see the
Accessories section
of this manual).
In a daisy chain configuration, a terminator must be used on both the first and last devices on the bus. One
of these devices may be the host adapter.
All other LF 6602's between the first and last device in the daisy chain should
not be terminated.
NOTE
Installation of both an active single-ended terminator and a passive
single-ended terminator on the same bus is not recommended.
If only one LF 6602 is attached to a host, the bus must be terminated at the host adapter and the LF 6602
host computer (refer to the next figure).
The SCSI bus must also be
terminated at the host
adapter end. Normally, the
termination function is built
into the host adapter.
TERMINATOR
Содержание LF 6602
Страница 1: ...THE PLASMON INFINITY LF 6602 OPTICAL DISK DRIVE User Manual P N 97654438 E...
Страница 6: ......
Страница 10: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 10...
Страница 20: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 20...
Страница 32: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 32...
Страница 42: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 42...
Страница 88: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 88...
Страница 92: ...PLASMON LASER MAGNETIC STORAGE LF 6602 USER MANUAL Page 92...
Страница 103: ......