9.3 Rear view
1 Ventilation slits
2 Suction port for the extraction system
3 Air pressure regulator
4 Ventilation fans
5 On/off switch
6 Connection panel
9.3.1 Air pressure regulator
The air pressure regulator with a condensate container for the compressed
air is located on the rear of the machine. It separates any remaining moisture
from the compressed air.
NOTE
Only use clean, dry and oil-free compressed air.
If water should collect in the sight glass, a drainage screw is located beneath
the sight glass. The condensate container can be emptied by turning the
screw, see section "Condensate container" on page 85.
9 Planmeca 60 S milling unit
User's manual
Planmeca PlanMill 60 S 27