Error
Cause
Solution
Contact personnel
Power button not
working
At least one motor
output stage signals a
fault
Diagnose fault cause
and remedy
User
Emergency stop not
released
Release the
emergency stop
User
Fuse triggered/
defective
Disconnect power plug,
check fuse
Electrician
Protective hood not
closed correctly
Close protective hood
User
Software not working
correctly
System is not switched
on
Switch on the system
(main switch)
User
Output stage is not
switched on
Switch on the output
stage (POWER button)
User
Connection between
control PC and
machine not correct
Contact Planmeca
After Sales and have
the output stage
replaced
User
Drive motor of an axis
does not react
No power supply to the
output stage, fuse
defective
Check fuses in the
switch cabinet or power
output stage
Electrician
Temperature protection
of the output stage is
active
•
Check fan in the
rear wall
•
Check / clean filter
in the fan
User
Output stage defective Replace output stage
(send in)
Electrician
Connection plug has
loosened
Check plug on the
control output and the
motor
Electrician
Cable break
Contact Planmeca
After Sales and have
the cable replaced
User
Protective hood not
closed correctly
Close protective hood
User
Processing machine
(spindle) not
functioning, i.e. cannot
be switched on
Not released by SC
module
Check spindle release
signal
User
Protective hood
interlocking not closed
Close protective hood
User
Protective hood not
closed correctly
Close protective hood
User
Emergency stop not
released
Release the
emergency stop
User
12 Troubleshooting
98 Planmeca PlanMill 50 S
User's manual