background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

 

 

 

 

 

F.

 

FAST START function 

With the FAST START function turned on, the waiting time for flame is shortened during the device start up. START UP function is 

factory-set. 

START UP function is possible to be turned on or turned off only when the green led is lit on the control panel 

To disable FAST START, hold down ECO button for about 10 s, until you hear 4 beeps. 

To re-enable the FAST START function hold down ECO button for about 10s, until you hear 2 beeps. 

WARNING! With FAST START function enabled, the device consumes 60 W of energy. 

 

G.

 

Information and warning alert 

In  order  to  increase  safety,  the 

PrimeFire

  is  equipped  with  an  electronic  system  to  keep  the  operation  safe.  In  the  case  of  a 

dangerous situation, the device immediately triggers alarms. 

 
LEGEND: 

 

 

 

 

 

READY

FUEL

HOT

HOT

HOT

HOT

The indicator is off 
 

The indicator flashes 
 

The indicator is blinking 
 

Содержание PrimeFire#4 Logs

Страница 1: ...USER S MANUAL PrimeFire 4 Logs Manufactured by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland Edition i1286 01 as of 30 10 2017 Serial number greater than P6210 17 ...

Страница 2: ... I General information 3 II Fuel 3 III Safety 4 IV Operation 5 A Operating elements 5 B Initial start up of the device 6 C Flame size regulation 7 D Device extinguishing 7 E Subsequent start up 7 F FAST START function 8 G Information and warning alert 8 V Cleaning and maintenance 10 VI Disposal and recycling 10 VII Service 10 ...

Страница 3: ...ts operators Manufacturer will not accept any responsibility in case of using any other fuel than recommended i e dehydrator and or super purified ethanol with more than 96 6 ethanol volume or any other which doesn t meet above mentioned properties Explanation of symbols is placed on the placed on the flap of the device It is forbidden to pour fuel into a burning device It is forbidden to pour fue...

Страница 4: ...uel FANOLA or the fuel recommended in section II Supplies and consumables Do not heat the fuel before the heating process of the device is started Do not start the device in case of spillage of fuel out of the tank Never pour fuel directly into the flame tray as this may cause damage to the device and result in fire Such an attempt may cause violent ignition result in fire burns and can even be li...

Страница 5: ...he device is properly installed according to the instructions and the manual A Operating elements Control Panel START STOP READY FUEL HOT ERROR PAT PEND ECO START STOP READY FUEL HOT ERROR PAT PEND ECO Fire grate Glowing coil Fanola filler bolt Furnace Logs Service USB input hidden under a cap Starts the device from standby mode or switches to the standby Switches to ECO mode The red indicator The...

Страница 6: ...e placed firmly in their place Place the stiff tube in the external fuel container from which the fuel will be pumped out into the PrimeFire s fuel tank To start the automatic pump squeeze the rubber manual pump several times until you will hear the buzzing noise Automatic fuel pump will start working once the fuel reaches the sensor inside the black box Pump will cease the refuelling process once...

Страница 7: ...w operating in ECO mode To return to the normal height of the flame press the ECO button you will hear one beep and the ECO button backlight turns off The device is now in normal mode ATTENTION It might take a few moments for the flame to adjust ATTENTION The device switches to ECO mode by itself when there is a danger of over temperature of the device D Device extinguishing Press the START STOP b...

Страница 8: ...hold down ECO button for about 10 s until you hear 4 beeps To re enable the FAST START function hold down ECO button for about 10s until you hear 2 beeps WARNING With FAST START function enabled the device consumes 60 W of energy G Information and warning alert In order to increase safety the PrimeFire is equipped with an electronic system to keep the operation safe In the case of a dangerous situ...

Страница 9: ...source of power needs to be disconnected Wait at least 1 hour to evaporate the remaining moisture and then close the fuel filler bolt If the alarm message reappears wait a little bit longer until the rest of the moisture evaporates If the message reappears contact your service provider The time given for the flame to appear has been exceeded If the alarm message appears during the start of the dev...

Страница 10: ...uation where it will be necessary to clean elements not normally available The manufacturer is not liable for damage resulting from improper operation non manual self dismantling attempts to modify using other liquids than those recommended in point II Fuel VI Disposal and recycling The product is equipped with parts made of aluminium steel plastics and electronics If you need to dispose of the de...

Отзывы: