7
•
In the case of GaLiO Fire Pit Corten powered with natural gas, to obtain the optimum image of the flame, cover
the burner with a single layer of decorative stones leaving some spaces uncovered of approximately every
2-3 cm (Photo 2).
Photo 2
•
If all the points were completed according to the instruction the gas bottle can be now
connected.
3.3.
Gas cylinder montage (only LPG version)
•
The gas linkage attached to the device allows to place the gas bottle maximally 3 meters away from the
connected control panel, however it cannot be placed nearer to the device than 1,5 meters.
Figure 2
•
The optional housing for the gas bottle cannot be airtight and has to be correctly ventilated. The housing needs
to have an upper ventilation slot above the top of the bottle (of an area min 1/100 of the area of the base of
the housing) and a lower ventilation slot (of an area min 1/50 of the area of the base of the housing). The
dimensions of the housing may vary to accommodate different types and dimensions of the gas bottles
however they also have to be sufficient for hassle-free installation of the gas bottle.