Planet VC-412 Скачать руководство пользователя страница 4

                                                                                                 

VC-412 User’s Manual 

 

4.4.2 Set Each VDSL Port Name of Unit ............................................................................................ 26

 

4.4.3 Display All Ports Status of Unit ................................................................................................. 27

 

4.4.4 Display All Trunks Status of Unit............................................................................................... 28

 

4.5 R

ESET 

T

D

EFAULT

............................................................................................................................ 29

 

4.6 R

EBOOT 

S

YSTEM

................................................................................................................................ 29

 

4.7 L

OGOUT

.............................................................................................................................................. 30

 

5. ICD COMMANDS FOR TELNET AND CONSOLE

......................................................................... 31

 

5.1 E

NTER 

ICD 

COMMAND LINE INTERFACE

............................................................................................. 31

 

5.2 ICD 

COMMAND 

I

NDEX 

T

ABLE

............................................................................................................ 32

 

5.3 S

ETTING 

VLAN F

UNCTIONALITY

....................................................................................................... 34

 

5.4 VDSL C

OMMAND

.............................................................................................................................. 36

 

5.5 P

ORT 

C

OMMAND

................................................................................................................................ 37

 

APPENDIX A – VC-412 FACTORY DEFAULT

..................................................................................... 39

 

APPENDIX B – UPDATE VC-101S FIRMWARE TO R4.5 REMOTELY THROUGH VC-412

....... 40

 

 

Содержание VC-412

Страница 1: ...Intelligent Ethernet over VDSL Switch VC 412 User s Manual ...

Страница 2: ...s operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his ...

Страница 3: ...2 2 1 VDSL PORT Information 12 3 2 2 2 TRUNK PORT INFORMATION 13 3 3 SYSTEM CONFIGURATION 13 3 3 1 System Configuration 13 3 3 2 Reset To Default 14 3 3 3 Reboot System 15 3 4 NETWORK CONFIGURATION 15 3 4 1 Protocol Control 15 3 4 2 SNMP Access Table 16 3 4 3 SNMP Trap Receiver Table 17 4 COMMANDS FOR CONSOLE AND TELNET 19 4 1 MAIN MENU SELECTIONS 19 4 2 MANAGEMENT CONFIGURATION 19 4 2 1 System Co...

Страница 4: ...4 5 RESET TO DEFAULT 29 4 6 REBOOT SYSTEM 29 4 7 LOGOUT 30 5 ICD COMMANDS FOR TELNET AND CONSOLE 31 5 1 ENTER ICD COMMAND LINE INTERFACE 31 5 2 ICD COMMAND INDEX TABLE 32 5 3 SETTING VLAN FUNCTIONALITY 34 5 4 VDSL COMMAND 36 5 5 PORT COMMAND 37 APPENDIX A VC 412 FACTORY DEFAULT 39 APPENDIX B UPDATE VC 101S FIRMWARE TO R4 5 REMOTELY THROUGH VC 412 40 ...

Страница 5: ...r Line or VDSL In simple terms VDSL transmits high speed data over short reaches of twisted pair copper telephone lines with a range of speeds depending upon actual line length By choosing the VC 412 VDSL Managerial Switch you have enabled your network to have the superb speed and manageability VC 412 offers 12 VDSL ports 12 POTS ISDN ports and 4 Ethernet ports for your VDSL solutions 1 1 Feature ...

Страница 6: ...glish Traditional Chinese Simplified Chinese Japanese SNMP Management Standard based SNMP MIB II and proprietary MIBs Supports TCP IP SNMP HTTP TFTP DHCP BOOTP Telnet protocols Twelve 12 VDSL Ports and Twelve 12 POTS ISDN Ports LED Sync Activity Error Maximum Distance 1 5 km Four 4 Ethernet Ports 10 100 Mbps Auto Negotiation IEEE 802 3 802 3u 802 3x LED Link Activity 10 100 Full Duplex Collision O...

Страница 7: ...lligent VDSL Switch 1 RS232 Male Console Cable DB9 to DB9 1 Setup and Installation Manual CD 1 Quick Installation Guide If any of these items are missing please contact your vendor immediately before continuing For additional manuals please contact your vendor Before removing the switch from the package please ensure to remove all static devices and static electricity from your body by touching an...

Страница 8: ...g data active LNK ACT Ethernet port Link Active Green Off No Ethernet link On The speed is 100Mbps 100 Ethernet port transmit and receive speed Green Off The speed is 10Mbps On Full Duplex Off Half duplex no collision FDX COL Ethernet port duplex mode Yellow Blinking Half duplex and transmission collisions have occurred VDSL Ports On VDSL link is established SYNC VDSL link Green Off No VDSL link O...

Страница 9: ...VC 412 User s Manual 5 Button Function Reset Push to reboot the switch Normal Uplink Normal When connect port D to PC or other end nodes Uplink When connect port D to other switch or hub ...

Страница 10: ...hen connect to the remote VDSL modems via telephone wires with a maximum distance up to 1 5 km The VC 412 takes approximately 15 seconds to start therefore when connecting the VC 412 to a remote modem such as the VC 101S it will take 15 seconds for link to be established VC 412 Ethernet Port D can serve as an uplink or a regular Ethernet port on when the Uplink button is pressed down it serve as a...

Страница 11: ...VC 412 User s Manual 7 2 2 Console Port Setup ...

Страница 12: ...e 1 None Once connected password authentication is required The default password is admin Console and Telnet share similar interfaces the main difference between them is that Console connects to the Switch directly through a cable Telnet connects to the switch remotely via an IP Address Therefore to use Telnet to access to the Switch you will first need to assign a valid IP address to the Switch t...

Страница 13: ...the standard Windows Telnet client Before using Telnet you must first know your Switch device IP address The IP should have been set earlier in the Console setup section If the IP address has not yet been set refer to the quick installation guide For Windows 95 98 NT 2000 XP A Press on Start Menu then on RUN type in telnet and the device IP address For example if the IP address is 192 168 0 1 type...

Страница 14: ...work statuses To log on to the VC 412 via HTTP you must first provide the IP address to the VC 412 The IP address should have been set earlier in the Console setup section If your IP has not been set please refer to the Console port section or the Defaults section in the Appendix A Note Please use MS Internet Explorer 5 5 or above to access to the VDSL Web page A Launch your Web browser B Enter th...

Страница 15: ...eliminary setup Important Username and password are both case sensitive Note Browsing is available without becoming an administrator by default However the administrator can turn off the browse option this will be discussed in later Set Value option is not available without entering the correct username and password Administrators will need to close browser to log out of administrator page ...

Страница 16: ...anel is the Reset Unit Counter option This option will reset the Receive Send and Collision counters for the unit Select the check box and press the Set Value button will reset the unit counter 3 2 2 Port Information 3 2 2 1 VDSL PORT Information Under the VDSL Port Information you will find a representation of the switch LED to indicate activity collision link etc Administrator is also able to en...

Страница 17: ...o monitor the Ethernet Link Active and Collision LEDs A green signal in the LED columns represents active status in the corresponding port and column 3 3 System configuration 3 3 1 System Configuration You will also notice the System link at the top frame select this link to change the system ...

Страница 18: ...itself to report back statuses and IP Address The System Configuration screen is illustrated below the settings are self explanatory 3 3 2 Reset To Default Also available under the System Link is the Reset to Default Reset to Default option will clear the VC 412 settings then restore the initial factory settings to it ...

Страница 19: ...ented with the selections shown below HTTP Login Username Set username for Web interface access to the VC 412 Note The password for the Http interface is the same as the console password HTTP Security When disabled you will allow users on your network to view settings and statuses of the VC 412 however modifications are prohibited unless users login through Become Administrator option When enabled...

Страница 20: ...with SNMP client access and protocols installed The VC 412 has been tested with HP OpenView and Windows NT SNMP client services and should be also compatible with most other SNMP client software However we do not recommend users to use Silvercreek SNMP client it has been found that it sometimes causes problem to the firmware The SNMP Access Table specifies addresses In Band or Out of Band of your ...

Страница 21: ...formation to the trap clients Currently the VC 412 offers 6 Trap Conditions in addition to port information and counters The 6 trap conditions are 1 Unit Up Power On and Check Status OK 2 Unit Down Error or Power Off 3 Port Link Up RJ 11 Plugged in and Link LED is On 4 Port Link Down RJ 11 is not plugged and Link LED is Off 5 Trunk Port Up RJ 45 is linked and Link ACT LED is On 6 Trunk Port Down R...

Страница 22: ...VC 412 User s Manual 18 Note Be sure to press the Set Value button at the bottom of the screen to administer the new settings failure to do so will result in lost of settings at refresh time ...

Страница 23: ...tting We will also list the ICD commands index in this chapter The ICD commands grant a variety of management controls and monitoring reports The following section will discuss the VC 412 Telnet menu structures and their functions Note Telnet will timeout and end its session on the VC 412 if no action is taken within one minute 4 1 Main Menu Selections 4 2 Management Configuration By choosing Mana...

Страница 24: ... change the basic settings such as IP Address Subnet Gateway etc as well as date and time and login password I Select the number you wished to edit and press Enter key Type in the new value and press Enter If you do not wish to change any information press Enter key without typing in any information ...

Страница 25: ...VC 412 User s Manual 21 Figure 24 II To change password select option 7 and press Enter key Type in the new password and press Enter III Enter the new password again to confirm ...

Страница 26: ...l apply to Console connection Telnet HTTP and SNMP client 4 2 2 Network Configuration Choosing the Network Configuration will allow you to set the access methods for administering the VC 412 as well as some future product enhancements HTTP Login Username Set username for Web interface access on ...

Страница 27: ... Managerial Switch however they will be unable to make changes unless they become an administrator by selecting the Become Administrator button in the Web interface BootP DHCP Control Obtain IP address from DHCP server Telnet Control Permit or forbid access to the VC 412 via the Telnet Console TFTP Upgrade Control Permit or forbid users to upgrade SNNP firmware via TFTP I To change login username ...

Страница 28: ...se fields This feature allows administrator to enter contact information and it is useful in situations where there is a problem with the unit or the network The customer can refer to this information from the Web interface or console to contact the vendor or installer To change this value select the option number and enter the new value then press Enter otherwise press Enter key without entering ...

Страница 29: ...anual 25 4 3 SNMP Access Table SNMP Trap Receive Control Table Choosing option 2 in the Main menu SNMP Access Table SNMP Trap Receive Control Table enables the administrator to set Community and SNMP Access properties ...

Страница 30: ...n Using the ICD Command Interface section In the section you will learn how to access the command line interface ICD command interface of the VC 412 and how to issue commands to the VC 412 via this interface 4 4 2 Set Each VDSL Port Name of Unit This option enables users to name or rename ports therefore offering a better port monitoring organization When asking for unit number please input 0 and ...

Страница 31: ...all twelve VDSL ports The three counter columns to the right of the status indicators report the amount of packets have received sent and collided Using these statistics you will be able to monitor your network status easily and quickly allowing you to alleviate network build up before problems occur ...

Страница 32: ...orts The three counter columns to the right of the status indicators report the amount of packets have received sent and collided Using these statistics you will be able to monitor your network status easily and quickly allowing you to alleviate network build up before problems occur The E L A C Column represents the current operating status of the ports E Enabled L Link A Activity C Collision Not...

Страница 33: ... other commands issued to the VC 412 will be lost by the reset Use this option only when there is a malfunction of the unit that prohibits it from functioning correctly after a reboot or power cycling 4 6 Reboot System The Reboot System command is used to reboot the OS but does not reset or change any settings of the VC 412 and its firmware On some occasions you will have to reboot the firmware Th...

Страница 34: ...ter finished issuing commands to the VC 412 it is recommended that you log out of the interface Logging out will ultimately end the session and require to re enter password to re login Note Make sure to save all changes before logging out ...

Страница 35: ...s accessing the command line interface within the switch and the commands available in this mode It is recommended that you read this section before proceeding into the command line interface 5 1 Enter ICD command line interface From the Main Menu Select option 3 for VDSL unit control Now select Option 1 to issue ICD Commands On Enter Unit Number prompt press 0 and Enter button to enter ICD comman...

Страница 36: ...nds ICD Console Command Description Index Table Command Description System Command Display command list U Display unit information S Save data to EEPROM This command will save VDSL and Trunk port settings Speed mode auto or preset modes only RS Reboot system RSW Restore factory defaults and reset the switch and ports This command will reset all VDSL ports settings to the following default VLAN ON ...

Страница 37: ...is for VC 101S firmware version R4 5 P is for firmware version R2 and Q is for firmware version R4 A Downstream 4 Mbps Upstream 1 Mbps R4 5 B Downstream 5 Mbps Upstream 5 Mbps R4 5 C Downstream 11 Mbps Upstream 11 Mbps R4 5 D Downstream 15 Mbps Upstream 17 Mbps R4 5 P Downstream 11 Mbps Upstream 11 Mbps R2 Q Downstream 15 Mbps Upstream 17 Mbps R4 Example LT 2 B will configure local port 2 s speed ...

Страница 38: ...tings when VLAN is ON Group 01 1 A D Group 02 2 A D Group 03 3 A D Group 04 4 A D Group 05 5 A D Group 06 6 A D Group 07 7 A D Group 08 8 A D Group 09 9 A D Group 10 10 A D Group 11 11 A D Group 12 12 A D Group 13 A B C D 5 3 Setting VLAN Functionality The VLAN function offers security and flexibility of controlling each port s access to one another This feature is useful in MDU and hotel situatio...

Страница 39: ...ible to all VDSL ports however it sometimes causes the switch to halt since the Ethernet port B and port C are designed for different purposes VC 412 also allows VLAN Grouping which enables user to define ports to communicate with each other while remaining isolated from the other ports outside the defined range traffic The VC 412 supports up to 16 different groupings and can only be set within th...

Страница 40: ...adjust the stream rate to the next higher speed mode If the next new stream rate failed then it will go back to speed level A LWD mode and progressively adjust to the last highest effective rate It will take approximately 10 seconds for the VC 412 to recalibrate to LWD mode This is called auto speed In some situations higher stream rate is reachable but line quality might be poor due to environmen...

Страница 41: ...llowing commands in the ICD command interface RT 10 B Connection will end LT 10 B Connection will re establish if within the range If connection does not establish with new speed level reset the switch and wait approximately 47 seconds for the switch and the remote modem to recalibrate 5 5 Port Command The P command displays all the VDSL ports status including its speed and speed mode AUT represen...

Страница 42: ...VC 412 User s Manual 38 The PC command displays all ports Transmit Receive and Collision statuses ...

Страница 43: ...VC 412 User s Manual 39 APPENDIX A VC 412 FACTORY DEFAULT Virtual LAN On Ethernet Speed 100 Full Half Duplex VDSL Port Line Rate Downstream at 4 Mbps Upstream at 1 Mbps IP Address 192 168 1 1 ...

Страница 44: ... of version R4 is 15 Mbps downsteam 17 Mbps upstream Therefore you will need to adjust both VC 412 and VC 101S to a complementary speed in order to establish link You can perform these procedures remotely via VC 412 console or telnet 1 Login to the VC 412 via console or telnet 2 Access to the ICD Command interface 3 Adjust the speed on VC 412 to the remote modem s speed with the following command ...

Страница 45: ...te modem s speed first is very important since connection will end once the remote modem s speed differs from the local switch 5 Now set the speed of VC 412 back to LWD mode Command Description LT port LWD speed mode Command LT 2 A Note Connection will re establish 6 Save remote modem s setting so it will not be lost upon power cycling Command Description SR port Command SR 2 7 Adjust the VC 412 b...

Страница 46: ...VC 412 User s Manual 42 For more detailed ICD command description please refer to the Chapter 5 ...