power connections, power losses or surges at power outlet. IF you still cannot resolve the problem, 

contact your local dealer for assistance. 

4.2.1 Cabling 

RJ-45 ports: use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 

100

 Category 3, 4 or 5 Cable for 10Mbps connections or 100

 Category 5 cable for 100Mbps 

connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters 

(328 feet). 

Diagnosing LED Indicators: the Switch can be easily monitored through panel indicators to assist in 

identifying problems, which describes common problems you may encounter and where you can find 

possible solutions. 

IF the power indicator does not turn on when the power cord is plugged in, you may have a problem with 

power cord. Than check for loose power connections, power losses or surges at power outlet. IF you still 

cannot resolve the problem, contact your local dealer for assistance. 

If the Industrial switch LED indicators are normal and the connected cables are correct and the packets 

still cannot transmit. Please check your system's Ethernet devices' configuration or status. 

Содержание IFT-802

Страница 1: ...Industrial 10 100Base TX to 100Base FX Media Converter IFT 802 User s Manual...

Страница 2: ...appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits...

Страница 3: ...roduct Specification 5 2 INSTALLATION 7 2 1 Product Description 7 2 2 Mounting Installation 11 3 Hardware Installation 14 4 TROUBLESHOOTING 16 4 1 Incorrect connections 16 4 2 Diagnosing LED Indicator...

Страница 4: ...HARDWARE NSTALLATION The chapter explains the functions of the Converter and how to physically install the Converter Chapter 3 NETWORK INSTALLATION The chapter explains how to install the Converter i...

Страница 5: ...s TP CAT 3 5 10 100Mbps Twisted Pair cable Auto MDI MDI X and Auto Negotiation Function Support Fiber Connector Multi Mode SC connector Architecture Store and forward Fiber Parameters Fiber Core Multi...

Страница 6: ...sumption 4 6 Watts Installation Provide DIN rail kit and wall mount plate for 3 way installation Operating environment 0 60 Degree C 5 90 RH Non condensing Storage environment 40 85 Degree C 5 90 RH N...

Страница 7: ...10 100Base TX Auto MDI MDIX to 100Base FX cabling It provides two power inputs that can be connected simultaneously to the DC power sources If one power input fails the other one acts as a backup The...

Страница 8: ...ure or Fiber port failure Fault Off No Power failure or UTP port failure or Fiber port failure occurs or the port alarm disable Green The port is linking with its link partner Blinks The port is trans...

Страница 9: ...rding When LLF is enabling allow UTP link failures to be reported to the fiber side and also allow Fiber link failure to be reported to the UTP side Therefore a link lost forward feature is provided i...

Страница 10: ...2 1 7 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as below figure shows By inserting the wires and set the DIPswitch at ON status it will detect...

Страница 11: ...Installation This section describes how to install the Converter and make connections to it Please read the following topics and perform the procedures in the order being presented 2 2 1 DIN Rail moun...

Страница 12: ...k Step4 To remove the Converter from the track reverse steps above 2 2 2 Wall Mount Plate Mounting To install the converter to the wall please follows the instructions described below Step1 Remove the...

Страница 13: ...he screws to screw the wall mount plate on the Converter Step4 Use the hook holes at the corners of the wall mount plate to hang the Converter on the wall Step5 To remove the wall mount plate reverse...

Страница 14: ...il is not screwed on the Industrial media converter If you want to wall mount the Industrial media converter then please refer to Wall Mount Plate Mounting section for wall mount plate installation St...

Страница 15: ...TP port RJ 45 LED on the Industrial media converter will light up when the cable connected with the switch Please refer to the LED Indicators section for LED light meaning Notice Be sure the connected...

Страница 16: ...ended tool for every 100Base T network installation 4 1 3 Improper Network Topologies It is important to make sure that you have a valid network topology Common topology faults include excessive cable...

Страница 17: ...ndicators the Switch can be easily monitored through panel indicators to assist in identifying problems which describes common problems you may encounter and where you can find possible solutions IF t...

Страница 18: ...3 6 21 3 6 There are 8 wires on a standard UTP STP cable and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection Figure A 1 Stra...

Отзывы: