4. TROUBLESHOOTING 

This section is intended to help you solve the most common problems on the Industrial Media Converter. 

4.1 Incorrect connections 

The switch port can auto detect straight or crossover cable when you link switch with other Ethernet 

device. For the RJ-45 connector should use correct UTP or STP cable, 10/100Mbps port use 2-pairs 

twisted cable. If the RJ-45 connector is not correct pin on right position then the link will fail.    For fiber 

connection, please notice that fiber cable mode and fiber module should be match. 

4.1.1 Faulty or loose cables 

Look for loose or obviously faulty connections. If they appear to be OK, make sure the connections are 

snug. IF that does not correct the problem, try a different cable. 

4.1.2 Non-standard cables 

Non-standard and miss-wired cables may cause numerous network collisions and other network problem, 

and can seriously impair network performance. A category 5-cable tester is a recommended tool for 

every 100Base-T network installation. 

4.1.3 Improper Network Topologies 

It is important to make sure that you have a valid network topology. Common topology faults include 

excessive cable length and too many repeaters (hubs) between end nodes. In addition, you should make 

sure that your network topology contains no data path loops. Between any two ends nodes, there should 

be only one active cabling path at any time. Data path loops will cause broadcast storms that will severely 

impact your network performance. 

4.1.4 Incorrect Power Input 

Verify that you are using the right power cord/adapter (DC 12-48V), please don't use the power adapter 

with DC output bigger than 48V, or it will burn this converter down. 

4.2 Diagnosing LED Indicators 

The Switch can be easily monitored through panel indicators to assist in identifying problems, which 

describes common problems you may encounter and where you can find possible solutions. 

IF the power indicator does turn on when the power cord is plugged in, you may have a problem with 

power outlet, or power cord. However, if the Switch powers off after running for a while check for loose 

Содержание IFT-802

Страница 1: ...Industrial 10 100Base TX to 100Base FX Media Converter IFT 802 User s Manual...

Страница 2: ...appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits...

Страница 3: ...roduct Specification 5 2 INSTALLATION 7 2 1 Product Description 7 2 2 Mounting Installation 11 3 Hardware Installation 14 4 TROUBLESHOOTING 16 4 1 Incorrect connections 16 4 2 Diagnosing LED Indicator...

Страница 4: ...HARDWARE NSTALLATION The chapter explains the functions of the Converter and how to physically install the Converter Chapter 3 NETWORK INSTALLATION The chapter explains how to install the Converter i...

Страница 5: ...s TP CAT 3 5 10 100Mbps Twisted Pair cable Auto MDI MDI X and Auto Negotiation Function Support Fiber Connector Multi Mode SC connector Architecture Store and forward Fiber Parameters Fiber Core Multi...

Страница 6: ...sumption 4 6 Watts Installation Provide DIN rail kit and wall mount plate for 3 way installation Operating environment 0 60 Degree C 5 90 RH Non condensing Storage environment 40 85 Degree C 5 90 RH N...

Страница 7: ...10 100Base TX Auto MDI MDIX to 100Base FX cabling It provides two power inputs that can be connected simultaneously to the DC power sources If one power input fails the other one acts as a backup The...

Страница 8: ...ure or Fiber port failure Fault Off No Power failure or UTP port failure or Fiber port failure occurs or the port alarm disable Green The port is linking with its link partner Blinks The port is trans...

Страница 9: ...rding When LLF is enabling allow UTP link failures to be reported to the fiber side and also allow Fiber link failure to be reported to the UTP side Therefore a link lost forward feature is provided i...

Страница 10: ...2 1 7 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as below figure shows By inserting the wires and set the DIPswitch at ON status it will detect...

Страница 11: ...Installation This section describes how to install the Converter and make connections to it Please read the following topics and perform the procedures in the order being presented 2 2 1 DIN Rail moun...

Страница 12: ...k Step4 To remove the Converter from the track reverse steps above 2 2 2 Wall Mount Plate Mounting To install the converter to the wall please follows the instructions described below Step1 Remove the...

Страница 13: ...he screws to screw the wall mount plate on the Converter Step4 Use the hook holes at the corners of the wall mount plate to hang the Converter on the wall Step5 To remove the wall mount plate reverse...

Страница 14: ...il is not screwed on the Industrial media converter If you want to wall mount the Industrial media converter then please refer to Wall Mount Plate Mounting section for wall mount plate installation St...

Страница 15: ...TP port RJ 45 LED on the Industrial media converter will light up when the cable connected with the switch Please refer to the LED Indicators section for LED light meaning Notice Be sure the connected...

Страница 16: ...ended tool for every 100Base T network installation 4 1 3 Improper Network Topologies It is important to make sure that you have a valid network topology Common topology faults include excessive cable...

Страница 17: ...ndicators the Switch can be easily monitored through panel indicators to assist in identifying problems which describes common problems you may encounter and where you can find possible solutions IF t...

Страница 18: ...3 6 21 3 6 There are 8 wires on a standard UTP STP cable and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection Figure A 1 Stra...

Отзывы: