User’s Manual of SGSW-24040 / 24240 Series
312
3
Optional
6.49 to 12.95 Watts (or to 15.4Watts)
Mid power
4
Optional
12.95 to 25.50 Watts (or to 30.8Watts)
High power
In this mode the
Maximum Power fields
have no effect.
Allocation mode
In this mode the user allocates the amount of power that each port may reserve. The allocated/reserved power for each
port/PD is specified in the Maximum Power fields. The ports are shut down when total reserved powered exceeds the
amount of power that the power supply can deliver.
In this mode the port power is not turned on if the PD requests more power the available.
Consumption mode
In this mode the ports are shut down when the actual power consumption for all ports exceeds the amount of power that the
power supply can deliver or if the actual power consumption for a given port exceeds the reserved power for that port. The
ports are shut down according to the ports priority. If two ports have the same priority the port with the highest port number
is shut down.
Priority mode
In this mode the user assign the priority to the ports/PD. When the total PoE power consumption request is over the allowed
power supply limitation, the system shut down PoE ports by port priority setting.
Ethernet Port Configuration
This section allows the user to inspect and configure the current PoE port settings
, screen in Figure 4-16-2 appears.
Figure 4-16-2
PoE Configuration screenshot
The page includes the following fields:
Содержание GSW-24040R
Страница 42: ...User s Manual of SGSW 24040 24240 Series 42 Figure 2 13 SGSW 24040 24040R Series Stack Ports ...
Страница 62: ...User s Manual of SGSW 24040 24240 Series 62 Figure 4 1 5 SGSW Managed Switch Main Functions Menu ...
Страница 142: ...User s Manual of SGSW 24040 24240 Series 142 Figure 4 6 10 Port 1 Port 6 VLAN Configuration ...
Страница 199: ...User s Manual of SGSW 24040 24240 Series 199 Figure 4 9 14 Voice VLAN Configuration page screenshot ...
Страница 223: ...User s Manual of SGSW 24040 24240 Series 223 Figure 4 11 4 Network Access Server Configuration page screenshot ...
Страница 260: ...User s Manual of SGSW 24040 24240 Series 260 Figure 4 12 1 Port Limit Control Configuration Overview page screenshot ...
Страница 452: ...User s Manual of SGSW 24040 24240 Series 452 Example Show RADIUS statistics SWITCH security aaa statistics ...
Страница 474: ...User s Manual of SGSW 24040 24240 Series 474 Parameters vid VLAN ID 1 4095 Default Setting disable ...
Страница 510: ...User s Manual of SGSW 24040 24240 Series 510 Example Enable the mirror mode for port 1 4 SWITCH mirror mode 1 4 enable ...