311
6~12 watts
Wireless LAN Access Points
Museum, Sightseeing, Airport, Hotel, Campus, Factory, Warehouse can
install the Access Point any where with no hesitation
10~12 watts
IP Surveillance
Enterprise, Museum, Campus, Hospital, Bank, can install IP Camera without
limits of install location – no need electrician to install AC sockets.
3~12 watts
PoE Splitter
PoE Splitter split the PoE 48V DC over the Ethernet cable into 5/9/12V DC
power output. It frees the device deployment from restrictions due to power
outlet locations, which eliminate the costs for additional AC wiring and reduces
the installation time.
4.16.2 Power Configuration
In a power over Ethernet system, operating power is applied from a power source (PSU-power supply unit) over the LAN
infrastructure to
powered devices (PDs)
, which are connected to ports. Under some conditions, the total output power required
by PDs can exceed the maximum available power provided by the PSU. The system may a prior be planed with a PSU capable
of supplying less power than the total potential power consumption of all the PoE ports in the system. In order to maintain the
majority of ports active, power management is implemented.
The PSU input power consumption is monitored by measuring voltage and current .The input power consumption is equal to the
system’s aggregated power consumption .The power management concept allows all ports to be active and activates additional
ports, as long as the aggregated power of the system is lower than the power level at which additional PDs cannot be
connected .When this value is exceeded, ports will be deactivated, according to user-defined priorities. The power budget is
managed according to the following user-definable parameters: maximum available power, ports priority, maximum allowable
power per port.
Reserved Power determined by
There are five modes for configuring how the ports/PDs may reserve power and when to shut down ports.
Classification mode
In this mode each port automatic determines how much power to reserve according to the class the connected PD belongs
to, and reserves the power accordingly. Four different port classes exist and one for 4, 7, 15.4 and 30.8 Watts.
Class
Usage
Range of maximum power used by the PD
Class Dsecription
0
Default
0.44 to 12.95 Watts
Classification unimplement
1
Optional
0.44 to 3.84 Watts
Very low power
2
Optional
3.84 to 6.49 Watts
Low power
Содержание GSW-24040R
Страница 42: ...User s Manual of SGSW 24040 24240 Series 42 Figure 2 13 SGSW 24040 24040R Series Stack Ports ...
Страница 62: ...User s Manual of SGSW 24040 24240 Series 62 Figure 4 1 5 SGSW Managed Switch Main Functions Menu ...
Страница 142: ...User s Manual of SGSW 24040 24240 Series 142 Figure 4 6 10 Port 1 Port 6 VLAN Configuration ...
Страница 199: ...User s Manual of SGSW 24040 24240 Series 199 Figure 4 9 14 Voice VLAN Configuration page screenshot ...
Страница 223: ...User s Manual of SGSW 24040 24240 Series 223 Figure 4 11 4 Network Access Server Configuration page screenshot ...
Страница 260: ...User s Manual of SGSW 24040 24240 Series 260 Figure 4 12 1 Port Limit Control Configuration Overview page screenshot ...
Страница 452: ...User s Manual of SGSW 24040 24240 Series 452 Example Show RADIUS statistics SWITCH security aaa statistics ...
Страница 474: ...User s Manual of SGSW 24040 24240 Series 474 Parameters vid VLAN ID 1 4095 Default Setting disable ...
Страница 510: ...User s Manual of SGSW 24040 24240 Series 510 Example Enable the mirror mode for port 1 4 SWITCH mirror mode 1 4 enable ...