Requirements for installation of heater units
8.1 Heater installation
Installation of the heater must be performed as shown on Fig. 8.1. The heater must be
installed onto level surface. Its intake must be oriented in such a way so no exhaust gases of
the vehicle and the heater itself could enter the intake during normal operation. Walls and
baffles may not be located closer than 100 mm from the intake and 250 mm from the outlet.
The intake and outlet must be provided with suitable protection against foreign objects
falling inside. To facilitate maintenance, install the heater in a way that allows easy
dismantling. During installation, ensure the heater casing does not contact either the floor or
other parts of the vehicle interior.
Attention! Operation of the heater depends on correct installation of the heating
element. The heating element must be installed horizontally as shown on Fig. 8.1.
Fig. 8.1 Heater installation
Floor installation
Wrong
Wrong