![background image](http://html.mh-extra.com/html/pjlink/dlp-mp-wu9101b/dlp-mp-wu9101b_user-manual_1561001077.webp)
77
Troubleshooting
Phenomenon
Cases not involving a machine defect
Reference
page
No image is
displayed via
HDBaseT.
Check the LAN cable if it is CAT5e certified or higher.
–
Try to change the LAN cable.
–
If the LAN cable is connected with more than 3 extension
connector, the transmission of 100 meters may fail.
–
Check if the extension connector is compatible with
CAT5e.
All LAN cable and extension connector connected with
HDBaseT
port must be CAT5e certified.
–
No image is
displayed via
SDI.
Check if it is connected with a cable of 5CFB or greater,
or Belden 1694A or greater.
–
Check if a cable with a length of 100m or less is used.
–
Try to change the cable.
–
Check if a supported signal format is input.
–
(continued on next page)
Phenomena that may be easy to be mistaken for machine defects (continued)