background image

6/12

Direct current: DC13

U

e

 (V) 

 24 

125  

250

I

e

 (A) 

  3 

0.55 

0.3

8.3.2 Versions with M12 connector, 4 or 5-pole:

Thermal current (I

th

):  

4 A

Rated insulation voltage (U

i

):  

250 Vac 300 Vdc

Protection against short circuits:  

type gG fuse 4 A 500 V

Pollution degree: 

3

Utilization categories:

Alternating current: AC15 (50÷60 hz)

U

e

  (V) 

24 

120  

250

I

e

 (A)  

 4  

  4   

  4

Direct current: DC13

U

e

 (V) 

 24 

125  

250

I

e

 (A) 

  3 

0.55 

0.3

8.3.3 Versions with M12 connector, 8-pole:

Thermal current (I

th

):  

2 A

Rated insulation voltage (U

i

):  

30 Vac 36 Vdc

Protection against short circuits:  

type gG fuse 2 A 500 V

Pollution degree: 

3

Utilization categories:

Alternating current: AC15 (50÷60 hz)

U

e

 (V) 

24

I

e

 (A)  

 2

Direct current: DC13

U

e

 (V) 

24

I

e

 (A) 

 2

8.4 Compliance with standards

EN 60947-5-1, EN 60947-1, EN 60204-1, EN ISO 14119, EN ISO 12100, EN 60529,  

BG-GSET-15, UL 508, CSA 22.2 N. 14.

8.5 Compliance with standards

Machinery Directive 2006/42/CE, EMC Directive 2014/30/UE, RohS Directive 

2011/65/UE.

 9 SPECIAL VERSIONS ON REQUEST

Special versions of the device are available on request.

The special versions may differ substantially from the indications in this instruction 

sheet.

The installer must ensure that he has received written information from the support 

service regarding installation and use of the special version requested.

 10 DISPOSAL

At the end of service life product must be disposed of properly, according to the rules 

in force in the country in which the disposal takes place.

 11 SUPPORT

The device can be used for safeguarding people’s physical safety, therefore in case of 

any doubt concerning installation or operation methods, always contact our technical 

support service:
Pizzato Elettrica Srl

Via Torino, 1 - 36063 Marostica (VI) - ITALY

Tel39.0424.470.930 

E-mail [email protected]

www.pizzato.com
Our support service provides assistance in Italian and English.

 12  EC CONFORMITY DECLARATION

I, the undersigned, as a representative of the following manufacturer:

Pizzato Elettrica Srl - Via Torino, 1 - 36063 Marostica (VI) – ITALY 

hereby declare that the product is in conformity with whatever prescribed by the 2006/42/

EC Machinery Directive. The complete version of the present conformity declaration is 

available on our website www.pizzato.com

Marco Pizzato

DISCLAIMER:
Subject to modifications without prior notice and errors excepted. The data given in this sheet are 
accurately checked and refer to typical mass production values. The device descriptions and its 
applications, the fields of application, the external control details, as well as information on installa-
tion and operation, are provided to the best of our knowledge. This does not in any way mean that 
the characteristics described may entail legal liabilities extending beyond the “General Terms of 
Sale”, as stated in the Pizzato Elettrica general catalogue. Customers/users are not absolved from 
the obligation to read and understand our information and recommendations and pertinent technical 
standards, before using the products for their own purposes. Taking into account the great variety of 
applications and possible connections of the device, the examples and diagrams given in the present 
manual are to be considered as merely descriptive; the user is deemed responsible for checking that 
the specific application of the device complies with current standards. This document is a translation 
of the original instructions. In case of discrepancy between the present sheet and the original copy, the 
Italian version shall prevail. The present manual may not be reproduced, in whole or in part, without 
the prior written permission by Pizzato Elettrica. 
© 2019 Copyright Pizzato Elettrica. All rights reserved.

- The stripping length of the cable or wire end sleeve (x) must be 7 mm (for contact 

blocks 20, 21, 22, 28, 29, 30, 33, 34) or 8 mm (for contact blocks 5, 6, 7, 9, 18).

x

x

6.6  Additional  prescriptions  for  safety  applications  with  operator  protection 

functions

Provided that all previous requirements for the devices are fulfilled, for installations 

with operator protection function additional requirements must be observed.

- The utilization implies knowledge of and compliance with following standards: 

EN 60947-5-3, EN ISO 13849-1, EN 62061, EN 60204-1, EN ISO 14119, 

EN ISO 12100.

6.7 Limits of use

- Use the device following the instructions, complying with its operation limits and the 

standards in force.

- The devices have specific application limits (min. and max. ambient temperature, 

mechanical endurance, IP protection degree, etc.)  These limitations are met by the 

device only if considered individually and not as combined with each other. 

- The manufacturer’s liability is to be excluded in the following cases:

1) Use not conforming to the intended purpose;

2) Failure to adhere to these instructions or regulations in force;

3) Fitting operations not carried out by qualified and authorized personnel;

4) Omission of functional tests.

- For the cases listed below, before proceeding with the installation contact our techni-

cal assistance service (see paragraph SUPPORT):

a) In nuclear power stations, trains, airplanes, cars, incinerators, medical devices 

or any application where the safety of two or more persons depend on the correct 

operation of the device;

b) Applications not contemplated in this instruction manual.

 7 MARKINGS

The outside of the device is provided with external marking positioned in a visible 

place. Marking includes:

- Producer trademark

- Product code

- Batch number and date of manufacture. Example: A19 FD1-123456. The batch's first 

letter refers to the month of manufacture (A=January, B=February, etc.). The second 

and third letters refer to the year of manufacture (19 = 2019, 20 = 2020, etc…).

 8 TECHNICAL DATA

8.1 Housing

FP series:

housing made of glass fibre reinforced technopolymer, self-ex-

tinguishing, shock-proof and with double insulation

1 threaded conduit entry M20x1.5 (standard)

Series FD, FC:

Metal housing, baked powder coating

1 threaded conduit entry M20x1.5 (standard)

FL series:

Metal housing, baked powder coating 

3 threaded conduit entries M20x1.5 (standard)

head:

Metal head, baked powder coating

Protection degree: IP67 acc. to EN 60529 

with cable gland of equal or higher protection degree

8.2 General data

Interlock with mechanical lock, coded: type 2 acc. to EN ISO 14119

Coding level:  

low acc. to EN ISO 14119

SIL (SIL CL):  

up to SIL 3 acc. to EN 62061

Performance Level (PL):  

Up to PL e acc. to EN ISO 13849-1

Safety parameters:

B10d 

(articles FD

 

••93, FL

 

••93, FP

 

••93, FC

 

••93)

: 2,000,000 for NC contacts

B10d 

(articles FD

 

••R2, FP

 

••R2, FD

 

••99, FP

 

••99)

: 1,000,000 for NC contacts

Mission time:  

20 years

Ambient temperature:  

-25°C … +80°C

Storage temperature:  

-40°C … +80°C

Max. actuation frequency:   

3600 operating cycles/hour

Mechanical endurance:  

1 million operating cycles

Max. actuation speed:  

0.5 m/s

Min. actuation speed: 

1 mm/s

Mounting position:  

any

Released actuator extraction force: max. 30 N

Maximum force before breakage F

1max 

(articles FD

 

••R2, FP

 

••R2, FD

 

••99, FP

 

••99)

:

 

1000 N acc. to EN ISO 14119

Max. holding force F

Zh 

(articles FD

 

••R2, FP

 

••R2, FD

 

••99, FP

 

••99)

 

770 N acc. to EN ISO 14119

8.3 Electrical data

8.3.1 Versions without connector:

Thermal current (I

th

): 

10 A

Rated insulation voltage (U

i

):  

500 Vac 600 Vdc

 

400 Vac 500 Vdc 

 

(contact blocks 20,21,22,28,29,30,33,34)

Rated impulse withstand voltage (U

imp

):   6 kV

 

4 kV

 

(contact blocks 20,21,22,28,29,30,33,34)

Conditional short circuit current:  

1000 A acc. to EN 60947-5-1

Protection against short circuits:  

type aM fuse 10 A 500 V

Pollution degree: 

3

Utilization categories:

Alternating current: AC15 (50÷60 hz)

U

e

  (V) 

250 

400  

500

I

e

 (A)  

  6  

  4   

  1

Содержание FC 93 Series

Страница 1: ...originali a basso livello di codifica devono essere smaltiti oppure resi inutilizzabili 4 2 Orientamento testa e dispositivo di sblocco dove presente possibile regolare la posizione della testa e del...

Страница 2: ...na in cui il dispositivo installato La conservazione delle presenti prescrizioni d impiego deve permettere la loro con sultazione per tutto il periodo di utilizzo del dispositivo 6 2 Non utilizzare ne...

Страница 3: ...P R2 FD 99 FP 99 1000 N secondo EN ISO 14119 Forza di ritenuta massima FZh articoli FD R2 FP R2 FD 99 FP 99 770 N secondo EN ISO 14119 8 3 Caratteristiche elettriche 8 3 1 Versioni senza connettore Co...

Страница 4: ...any bypassing of the safety device If new actuators are fitted the original low level coding actuators must be disposed of or rendered inoperable 4 2 Head and release device where present orientation...

Страница 5: ...ete or chemicals are spread In environments where continual changes in temperature cause the formation of condensation inside the device In environments where the application causes collisions impacts...

Страница 6: ...erved The stripping length of the cable or wire end sleeve x must be 7 mm for contact blocks 20 21 22 28 29 30 33 34 or 8 mm for contact blocks 5 6 7 9 18 x x 6 6 Additional prescriptions for safety a...

Страница 7: ...de s curit En cas d installation de nouveaux actionneurs les actionneurs d origine faible niveau de codification doivent tre limin s ou rendus inutilisables 4 2 Orientation de la t te et du dispositi...

Страница 8: ...rs joindre les pr sentes prescriptions d utilisation au manuel de la machine sur laquelle le dispositif est install La conservation des pr sentes prescriptions d utilisation doit permettre de les cons...

Страница 9: ...ontage quelconque Force d extraction de l actionneur d verrouill 30 N max Force maximale avant la rupture F1max articles FD R2 FP R2 FD 99 FP 99 1000 N selon EN ISO 14119 Force de retenue maximale FZh...

Страница 10: ...soliert und konstant berwacht werden um eine Umgehung der Sicherheits Vorrichtung zu verhindern Sobald neue Bet tiger montiert werden m ssen die Original Bet tiger mit niedriger Kodierungsstufe entsor...

Страница 11: ...nisch Sollte der Installateur die Produktdokumentation nicht eindeutig verstehen muss er die Montage unterbrechen und sich an den Kundendienst wenden vgl Abschnitt KUNDENDIENST Wird das Ger t auf eine...

Страница 12: ...Umgebungstemperatur 25 C 80 C Lagertemperatur 40 C 80 C Maximale Bet tigungsfrequenz 3600 Schaltspiele Stunde Mech Lebensdauer 1 Million Schaltspiele Max Bet tigungsgeschwindigkeit 0 5 m s Min Bet ti...

Отзывы: