User manual - STR561 -
31
Modbus
Address
Description
Read
Write
Reset value
9003 Data logger: sensor type (L)
RO EEPROM
9004 Data logger: sensor type (H)
RO EEPROM
9005 Data logger: decimal point (L)
RO EEPROM
9006 Data logger: decimal point (H)
RO EEPROM
9007 Data logger: measure unit (L)
RO EEPROM
9008 Data logger: measure unit (H)
RO EEPROM
9009 Data logger: sampling time in seconds (L)
RO EEPROM
9010
Data logger: sampling time in seconds (H)
RO EEPROM
9011
Data logger: flag end memory. 0 indicates that
memory is still available. 1 indicates memory is
saturated and device restarted to store data from
address 9033/9034 (L)
RO EEPROM
9012
Data logger: flag end memory. 0 indicates that
memory is still available. 1 indicates memory is
saturated and device restarted to store data from
address 9033/9034 (H)
RO EEPROM
9033 First analogue input value stored (L)
RO EEPROM
9034 First analogue input value stored (H)
RO EEPROM
9035 Second analogue input value stored (L)
RO EEPROM
9036 Second analogue input value stored (H)
RO EEPROM
...
...
RO EEPROM
10031 Last analogue input value stored (L)
RO EEPROM
10032 Last analogue input value stored (H)
RO EEPROM
* Parameters modified using serial address 4001 to 4300 and 5001 to 5300, will be stored on
eeprom only after 10s since last writing of one parameter.
Содержание STR561
Страница 1: ...STR561 Indicator Indicatore User manual Manuale installatore...
Страница 2: ......
Страница 107: ...Manuale d uso STR561 107 Note Aggiornamenti...
Страница 111: ......