RS-485 In/ Out Jack
:
- RS-485 Input (TXDI+, TXDI-) to receiver signal from
keyboard, matrix, DVR or multiplexer through twisted
pair cable.
- RS-485 Output (TXDO+, TXDO-) sending out signal to
next PIXORD NDC through twisted pair cable.
- Recommend Data Cable:
2547 VW-ISC UL 24 AWG x 2C
- Transmission Distance: Max. 1 Kilometer
*When 24VAC PSU is used, the recommend cables are:
UL SPT-1 VW-1 18AWG x 2C
UL SPT-2 VW-1 18AWG x 2C
UL SUT 105C VW-1 18AWG x 3C
The distance between 24Vac PSU and fast dome cannot exceed 200 meters.
Ethernet:
Standard IEEE802.3 10 Base T port
POWER/STATUS LED:
-
Power On: constant red.
- Emergency factory default (appendix C): Blinking orange (i.e. red mix with green).
NETWORK LED:
- Network Link (connected): Constant red.
- Networks have activities: Blink red.
- Data sent out from server: Blink green.
- Network disconnected: Constant slow blinking green.
- Upgrading software (appendix A): Constant slow to fast blinking of orange.
9