Flex-View Event Presentation Switching Solution
User Manual
5 Hardware Introduction
www.pixelhue.com
19
Rear panel LED work lights
Power Connectors
The F4 is equipped with dual redundant power supplies. The load is shared equally by
both power supplies during normal operation. If one fails or is disconnected, the
other one carries the whole load. Connect both power connectors to the electrical
outlets through the provided power cords.
Power specification: 100–240V~, 50/60Hz, 10A–5A
On each power module, there is a dual color LED on its front face, providing the
power supply status information as follows:
Green: The power supply works normally.
Flashing green: The AC power is applied to the power supply unit and the
standby voltage is available.
Orange: The power supply fails or is disconnected.
Flashing orange: Warning occurs on the power supply unit, such as high
temperature, over current, fan failure and so on; therefore a replacement of the
unit may be necessary.
Off: No AC is power is connected to the power supply unit.
Control Card
The control card provides an Ethernet port, two type-A USB ports, a type-B USB port, a
Genlock connector with loop-through, a control UI connector and a pinhole reset hole
(button).
Ethernet Port
An Ethernet port is provided for connection with the control PC or for input view.
USB Ports (Type-A)
Two type-A USB ports are provided for firmware update and importing/exporting files
by using a USB drive.