ELECTRIC 

SHOCK

Electrocution 

or death

F

This equipment must be grounded.  Improper grounding, setup or usage of 

the system can cause electric shock.

Turn off and disconnect power cord before servicing  equipment.

Connect only to a grounded electrical outlets.

Use only 3 wire extension cords in accordance with local electrical codes. 

Extension cords should have a ground lead.

Ensure ground prongs are intact on power and extension cords.

Do not expose to rain.  Store indoors.

Never touch the electric plug of socket with wet hands. 

Do not turn the dispensing system on if the power connection cord or other 

important parts of the apparatus are damaged, such as the inlet outlet plumb-

ing, dispensing nozzle or safety devices.  Replace damaged components be-

fore operation.

Before each use check that the power connection cord and power plug are 

not damaged.  If damaged, have power connection cord replaced before use 

by a qualified electrician.

The electrical connection between the plug and socket must be kept well 

away from water.

Unsuitable extension leads can be hazardous, in accordance with current regulations. 

only extension cords that are labelled for outdoor use and have a sufficient conduc-

tion path should be used outdoors.

For safety reasons, we recommend that, in principle, the equipment be used only with a earth-

leakage circuit breaker (max 30 mA).

Electrical connections must use ground fault circuit interrupter (GFCI).

Installation operations are carried out with the box open and accessible elec-

trical contacts. All these operations have to be done with the unit isolated 

from the power supply to prevent electrical shock!

EQUIPMENT 

MISUSE

Misuse can 

cause death or 

serious injury

!

Do not operate the unit when fatigued or under the influence of drugs or 

alcohol.

Do not leave the work area while equipment is energized or under pressure.

Turn off all equipment when equipment is not in use.

Do not alter or modify equipment.  Alterations or modifications may void 

agency approvals and create safety hazards.

Route hoses and cables away from traffic areas, sharp edges, moving parts, 

and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

Burn Hazard

Equipment surfaces and fluid that is heated can become very hot during 

operation

To avoid severe burns do not touch hot fluid or equipment.

Toxic Fluid or 

Fumes Hazard

Read MSDS’s to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers, and dispose of it according to 

applicable guidelines.

Prolonged contact with the treated product may cause skin irritation: always 

wear protective gloves during dispensing.

Содержание SUZZARABLUE BASIC

Страница 1: ...SUZZARABLUE SIDE PRO BASIC Bulletin M0195B USA_00 Installation use and maintenance EN SB_D_011 DEF 3A LN DEF6 LN Installation Use and Maintenance Manual aka M0195 B ...

Страница 2: ...M0195 b 2 20 Installation use and maintenance Bulletin M0195B ENGLISH ...

Страница 3: ...SPENSING SYSTEM PACKAGING 7 4 1 PACKAGE CONTENTS PRE INSPECTION 7 4 2 SIDE CONSISTS OF 8 5 MACHINEANDMANUFACTURERIDENTIFICATION 8 5 1 PLATES POSITION 9 6 TECHNICAL SPECIFICATIONS 10 7 INTENDED USE 10 8 TREATED PRODUCT CHARACTERISTICS 11 9 INSTALLATION 11 10 ASSEMBLY 12 11 INSTALLATION ONTO IBC TANKS 13 12 OPERATION AND USE 14 13 LEAVING THE SYSTEM UNUSED FOR LONG PERIODS OF TIME 16 14 WASHING THE ...

Страница 4: ...d by applicable laws including by way of example laws on copyrights All the rights deriving from such laws are reserved to Piusi S p A the reproduction including par tial of this manual its publication change transcription and notification to the pub lic transmission including using remote communication media placing at disposal of the public distri bution marketing in any form translation and or ...

Страница 5: ...ufficient conduc tion path should be used outdoors For safety reasons we recommend that in principle the equipment be used only with a earth leakagecircuitbreaker max30mA Electrical connections must use ground fault circuit interrupter GFCI Installation operations are carried out with the box open and accessible elec trical contacts All these operations have to be done with the unit isolated from ...

Страница 6: ...ing products Personal protective equipment that must be wor Wear the following personal protective equipment during handling and instal lation Safety shoes Close fitting clothing Protective gloves Safety goggles Other equipment Instruction manual Protective gloves Prolonged contact with the treated product may cause skin irritation always wear protective gloves during dispensing WARNING Never touc...

Страница 7: ...omes packed in a card board box bearing the fol lowing markings an arrow indicating the TOP side a label containing all the information relating to the equipment model weight etc SB_D_001 4 1 PACKAGE CONTENTS PRE INSPECTION Foreword To open the cardboard packaging use a pair of scissors or a cutter being careful not to damage the dispensing system or its components Open the packaging and check tha...

Страница 8: ...LUE DOSING SYSTEM 6 NO OR SEALS 13 USE AND MAINTENANCE HANDBOOK FOR METER K24 PRO VERSION 7 NO 2 RING NUTS FOR SWIVEL PLASTIC 14 SUCTION CONNECTION DEVICE 5 MACHINEANDMANUFACTURERIDENTIFICATION The dispensing system comes with an identification plate this is attached to the pump and contains the following information type lot number Production year technical data use and maintenance handbook code ...

Страница 9: ...er time NOTE Should this situation arise please contact our support department and ar range to have the damaged or missing plates sent back and replaced where necessary The decals present are as follows nlr m 230 V 50 Hz 520W 2 4A 2900 Rpm 40 l min 3 5 bar IP55 5 40 C nlr m 1 protection gloves safety goggles close fitting clothing consult the user and maintenance manual safety shoes 230 V 50 Hz 52...

Страница 10: ...ure of dispensed product permitted by materials 40 C Voltage variation permitted 5 Equivalent continuous sound pressure level at the workstation 75 dB A Make sure that the pump operates within its nominal operating parameters Flammable liquids and explosive atmo sphere The system SUZZARABLUE was not designed for dispensing of diesel petrol flammable liquids with flash point 55 C 131 F or for opera...

Страница 11: ...BC tank installation Any different form of installation must guarantee secure fastening Authorised installation personnel All installations must be carried out by authorised and competent personnel only Authorised persons must install the system in dry and well ventilated place ensure the correct installation of equipment required for the correct func tioning of the pump only use accessories that ...

Страница 12: ... 10 ASSEMBLY Assemble as shown intheillustration See components number at the cap 4 2 ATTENTION The SUZZARABLUE dispensing system is equipped with an IBC tank suc tion connection device This must be installed before attempting to operate the system ...

Страница 13: ...om Italian 11 INSTALLATION ONTO IBC TANKS NOTE Different forms of installation i e without the tanks indicated are only permitted if they are capable of guaranteeing that the dispensing system will be firmly and stably fastened Use the hooks and rope provided to firmly and stably fasten the dispensing system to the tank SB_D_005 pipe support ...

Страница 14: ...without dispensing is only admitted for periods of no longer than 3 minutes WARNING We recommend that the pump remains switched off whenever the system is not in use ATTENTION If ever the voltage is lagging push the switch to the OFF position and return the nozzle to its rest position with its lever not activated Getting started EMPTY NOZZLE HOLDER SB_D_005 SB_D_011 ATTENTION Should any sealants b...

Страница 15: ...5 20 EN This manual is the property of PIUSI S p A Any reproduction even partial is forbidden suzzarablue side pro basic Translated from Italian AUS32 DIESEL 20 MAX 230V 50Hz ONLY SB_D_005 ON OFF SUCTION SYSTEM ...

Страница 16: ...c tions The dispensing system was designed and built to require a minimal amount of maintenance Before carrying out any maintenance work disconnect the dispensing system from any electrical and hydraulic power source During maintenance the use of personal protective equipment PPE is compulsory In any case always bear in mind the following basic recommendations for a good func tioning of the pump A...

Страница 17: ...ith the by pass open Use shorter tubing or of greater diameter By pass valve blocked Contact the Service Department Air entering the pump or the suc tion tubing Check the seals of the connec tions A narrowing in the suction tubing Use tubing suitable for working under suction pressure Low rotation speed Check the voltage at the pump Adjust the voltage and or use cables of greater cross section The...

Страница 18: ... EU requires that all equipment marked with this symbol on the product and or packaging not be disposed of together with non differentiated urban waste The symbol indicates that this product must not be disposed of together with normal household waste It is the responsi bility of the owner to dispose of these products as well as other electric or electronic equipment by means of the specific refus...

Страница 19: ...This page left intentionally blank ...

Страница 20: ... USA_00 en EN This document has been drawn upwith the greatest attention to precision and accuracy of all data herein contained Nevertheless PIUSI S p A denies liability for any possible mistake or omission PIUSI S p A ...