M0195 b
16
/20
Installation, use and maintenance
13
LEAVING THE SYSTEM UNUSED FOR
LONG PERIODS OF TIME
What to do
Whenever it is thought that the system will remain unused for at least 15 days,
it must be emptied in order to prevent the product from crystallising inside.
This shall be followed by a washing cycle..
14
WASHING THE DISPENSING SYSTEM
Foreword
The dispensing system requires washing in order to remove product crystal-
lisation which may damage the plant.
ATTENTION
Wear personal protective equipment (PPE) when performing the wash
cycle.
Use only demineralised water to wash the system.
DISPOSAL
Liquids resulting from washing must be disposed of in accordance with the
laws prevailing in the country of use.
ATTENTION
By following the same modes of delivery described above, the dispensing
system can be washed by sucking up demineralised water from the clean con-
tainer and collecting the resulting mixture in a different disposable container.
SB_D_015
15 MAINTENANCE
Safety instruc-
tions
The dispensing system was designed and built to require a minimal amount of maintenance.
Before carrying out any maintenance work, disconnect the dispensing system from
any electrical and hydraulic power source.
During maintenance, the use of personal protective equipment (PPE) is compulsory.
In any case always bear in mind the following basic recommendations for a good func-
tioning of the pump
Authorised
maintenance
personnel
All maintenance must be performed by qualified personnel.
Tampering can lead to
performance degradation, danger to persons and/or property and may result in the
warranty being voided.
Measures to be
taken
Whenever there is risk of frost, empty the circuit and the pump, taking care to place
the pump in an environment where the temperature is no lower than 0°C/32°F.
Check that the labels and plates found on the dispensing system do not deteriorate
or become detached over time.
ONCE A
WEEK:
- Check that the pipe connections are not loose to prevent any leaks;
- Check and keep the filter installed on the suction line clean.
ONCE
A MONTH:
- Check the pump body and keep it clean and free of any impurities;
- Check that the electrical supply cables are in good condition.