SV60890 Rev. G
9-9
DM500™and DM550™ Digital Mailing System Operating Guide
9. After cleaning the wick and
tank, place the shield on the
wick, making sure that there is
no gap between the shield and
the surface of the wick.
6. Drain the moistener tank over
the front of the machine into a
receptacle as shown here.
7.
To clean the moistener tank,
remove the E-Z Seal® Sealing
Solution supply tube and wipe
out the tank with E-Z Seal®
solution.
Clean the wick by holding it un-
der running water.
8. Push the supply tube back
onto the moistener tank noz-
zle. Push the tube back on as
far as it will go to prevent leak-
ing.
Cleaning or
Replacing the
Wick
continued
Содержание DM500
Страница 1: ...Digital Mailing System DM500TM and DM550TM Operator Guide US English Version ...
Страница 2: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 132: ......
Страница 172: ......
Страница 173: ...SV60890 Rev G A 1 Glossary A ...
Страница 180: ......
Страница 189: ...SV60890 Rev G C 1 Specifications C 2 Mailing Materials C 4 Envelope Dimensions C 5 Specifications Contents C ...
Страница 194: ......
Страница 195: ...SV60890 Rev G i 1 Index ...