TROUBLESHOOTING
PROBLEM
CAUSE
CORRECTIVE ACTION
Grill or side cooker
will not light.
The ignition wire came off the
electrical igniter/valve.
Reconnect the ignition wire to the electrical igniter/
valve.
The distance between the ignition pin
and the burner is greater than 5/32 in.
to 3/16 in. (side burner).
Loosen the ignition pin, adjust the distance, then
tighten.
The ignition wire is broken.
Call Customer Service for replacement.
The battery has died.
Install a new battery.
The new battery does not work.
Check the battery polarity. The negative (-) side of the
battery goes in first.
The electrode tip does not produce
sparks at the burner port.
Reinstall the electrode.
No gas supplied.
Check the regulator valve. Check connection for leak.
Excessive flare-up.
Grilling fatty meats.
Grill fatty meats when the grids are cold, and the
knobs are on the “LOW” setting. Move the meats to the
warming rack if flare-up continues.
Controls are on “HIGH”.
Before you are ready to grill, turn the knobs to the “OFF”.
Water sprayed on gas flames.
Do not spray water on gas flames.
Hood closed when grilling.
Hood up when grilling.
Burner blows out.
LP tank is empty.
Refill the LP tank.
Burner is not aligned with the control
valve.
Install the burner correctly.
Gas supply is not sufficient.
Check the gas supply hose and make sure there are no
leaks and no knots.
Low heat when on
“HIGH”
Ports are blocked.
Clear ports of any obstructions.
LP tank has run out.
Refill the LP tank.
Low Heat, LP gas.
The propane regulator assembly
incorporates an excess flow device
designed to supply the grill with
sufficient gas flow. Rapid changes in
pressure can trigger the excess flow
device, providing a low flame and low
temperature.
1. Make sure all burners are “OFF.”
2. Open the tank valve and wait 5 minutes.
3. Light each burner, one at a time, following the
lighting instructions.