8
Type
Low vacuum, 60L
Configuration
RPV062-60T200
RPV062-60S100(S100SW
(
*2
)
)
RPV062-60S110
Number of rotor
Twin (2)
Rotor layout
Parallel layout
Pumping speed (L/min)
50
㎐
60
60
㎐
72
Final vacuum (Pa abs)
50
㎐
≦
3,500
60
㎐
≦
3,000
Final vacuum (kPa G)
50
㎐
≦
-97.8
60
㎐
≦
-98.3
Max. vacuum pressure
Atmospheric pressure
Ambient temp. (indoor) (ºC)
5
~
40
Ambient humidity (indoor)
Maximum 85%RH (no dew condensation)
Gas (inhaled gas)
No corrosive / exposable gas
Vibration of installation site
Max 4.9m/s
2
(10~60Hz)
Altitude of installation site
1000meter or less above sea level
Install orientation
Horizontal installation of the motor axis (shaft)
M
ot
or
Output (W)
60
Type
3 phase motor built-in thermal
protector, Heat proof class 130(B)
Capacitor-start single phase induction motor built-in thermal
protector, Heat proof class 130(B)
Voltage (V)(*3)
200
/
220
/
230
100
110/115
Rated current (A)
50
㎐
0.45
/
ー
/
ー
1.3
ー
60
㎐
0.41
/
0.40
/
0.41
1.2
1.1/1.2
Rated rotation speed
(min¯¹)
50
㎐
1,350 /
ー
/
ー
1,250
ー
60
㎐
1,625 / 1,650 / 1,675
1,575
1,625/1,625
Striking current (A)
50
㎐
1.3
/
ー
/
ー
2.4
ー
60
㎐
1.2
/
1.3
/
1.4
2.3
2.5/2.6
Operation noise
(dB(A))(*1)
50
㎐
≦
58
ー
60
㎐
≦
63
Vacuum port size
G1/ 2
Exhaust port size
G3 / 8
Dimensions (width x depth x height) (mm)
125
×
299.6
×
176
(
S100SW
(
*2
):
125
×
299.6
×
180.8
)
Weight (kg)
7.5
(
S100SW
(
*2
):
7.9 (* including attachments))
Cooling system
Forced air cooling
*1) Operating noise is the maximum measured value in load variation, which excludes the suction noise and exhaust noise by centralized piping,
and is not a guaranteed value.
*2) A model with a built-in power switch. Not corresponding to CE marking.
*3) Allowable intermittent power supply voltage fluctuation range is ±10% of the specified voltage; allowable sustained supply voltage fluctuation
range is
±
3% of the specified voltage.
Rotary Vacuum Pump
Specification(Low Vacuum)
OUT
IN
Содержание RPV06 Series
Страница 28: ...28 Rotary Vacuum Pump Memo ...