6
Thermal protector
MCCB
Relay
(
Ry
)
SW B
Ry
Ry
Ry
SW A
Capacitor
Blue (P)
White (U1)
Gray (U2)
Black (Z2)
Blue (P)
Motor
S
in
gl
e-
ph
as
e
po
w
er
s
ou
rc
e
Thermal protector
SW
E
L
N
Capacitor
Fuse
(
5A
)
Blue
(
P
)
White
(
U1
)
Gray
(
U2
)
Black
(
Z2
)
Blue
(
P
)
Motor
3-pin power cable connection
MCCB
S
R
T
U
V
W
Motor
Thermal protector
Thermal protector
3-
ph
as
e
po
w
er
s
ou
rc
e
Blue (P)
Blue (P)
Black(W)
Gray (V)
White (U)
SW A
Ry
Ry
SW B
MCCB
Ry
Ry
R
S
T
3-phase power source
Relay
(
Ry
)
Thermal protector
Motor
■
Single phase motor with a built-in power switch wiring diagram (RPV06A-40S100SW, RPV062-60S100SW)
■
3-phase motor wiring diagram (RPV064-120)
The motor is equipped with an automatic reset type thermal protector in the coil. Therefore, operation restarts automatically when the temperature of the motor
drops to safety level after thermal protector activation. To prevent a danger by unexpected restart, provide a recovery switch which uses switch and relay as like
above circuit diagram to restart the pump.
●
Thermal protector activation temperature : Open (motor stop)
▶
130
±
5ºC, Close (motor restart)
▶
90
±
15ºC
Note: The motor is equipped with an automatic reset type thermal protector in the
coil. Thermal protector activates to stop the motor in case the temperature
inside the motor exceeds the specified temperature below. Operation
restarts automatically when the temperature of the motor drops to safety
level. To prevent a danger by unexpected restart, make sure to turn off the
main power supply before maintenance and inspection.
●
Thermal protector activation temperature
Open (motor stop)
▶
130
±
5ºC, Close (motor restart)
▶
90
±
15ºC
Note: Therefore, in the case of the circuit (left figure) given in the handling
instruction of motor, after activation of thermal protector, operation will be
resumed automatically when motor temperature falls.
In order to prevent a risk by unexpected reboot, please take safety
measures when operating the pump, such as making a self-hold circuit
using relays and switches.
●
Thermal protector activation temperature
Open (motor stop)
▶
130
±
5ºC, Close (motor restart)
▶
86
±
20ºC
①
②
③
③
④
④
⑤
⑱
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
⑮
⑯
⑰
⑱
⑲ ⑳
⑦ ⑨
Rotary Vacuum Pump
No.
Part description
Material
①
Cyliner
Aluminum alloy
②
Rotor
PPS resin
③
Bearing
Stainless steel
④
Crank plate
Stainless steel
⑤
Main shaft
Stainless steel
⑥
Side block E
Aluminum alloy
⑦
Bearing
Stainless steel
⑧
Blancer E
Stainless steel
⑨
Blancer R
Stainless steel
⑩
Side plate
Aluminum alloy
⑪
Center plate
Aluminum alloy
⑫
Manifold
Aluminum alloy
⑬
Side block M
Aluminum alloy
⑭
Magnet
Neodymium magnet
⑮
Cooling fan
PPS resin
⑯
Sealing cup
PPS resin
⑰
Motor
Aluminum alloy
⑱
Cap screw
Stainless steel
⑲
Inner coupling
Stainless steel
⑳
Magnet
Neodymium magnet
* All seal rubber is made of FKM.
Structure
(e.g. parallel twin - 60W motor type: RPV062-60)
Motor Wiring diagram
■
Single phase motor wiring diagram (RPV06A-40S100/S110, RPV062-60S100/S110)
■
3 phase motor wiring diagram (RPV06A-40T200, RPV062-60T200, RPV063-90T200)
Содержание RPV06 Series
Страница 28: ...28 Rotary Vacuum Pump Memo ...