Caution Messages
The Caution and Warning panel is not altered as part of this
modification and remains the primary means of providing Caution
and Warning messages.
Caution and Warning messages are provided in the following table:
EXCEEDANCES | WARNINGS
RED
Short Text
Lon
g Text
Comments
Terrain Pull-Up*
Terrain Pull-Up
The FLTA algorithm has detected
an imminent ground collision -
Initiate an immediate recovery
maneuver.
Warning
Obstacle*
Warning Obstacle
The FLTA algorithm has detected
an imminent obstacle collision.
Initiate an immediate recovery
maneuver.
Unit Overtemp –
Unit Unreliable
Unit Overtemp: <internal
component name> Unit
reliability in question –
Get IFD serviced
One or more of the internal
components has exceeded its
maximum design temperature and
reliability cannot be ensured until
the unit is tested by the Avidyne
Service Center.
Contact the Avidyne Service
Center or a local dealer for
service. This message will be
present on every subsequent
power cycle until reset by the
Avidyne Service Center.
Low Volts – off in
<countdown from
60> sec
Low Volts – IFD powers
down in <countdown
from 60> sec
Main supply voltage has fallen
below 9 VDC. Contact a local
dealer for service.
Pull Up
Excessive Descent Rate
The TAWS Excessive Descent
Rate algorithm has detected a
CFIT potential – initiate an
immediate recovery maneuver.