installation manual
To guarantee proper installation, please first read this
"installation manual" in its entirety.
The air conditioner must be installed by qualified persons.
When installing the indoor unit or its tubing, please follow
this manual as strictly as possible.
If the air conditioner is installed on a metallic part of the
building, it must be electrically insulated according to the
relevant standards for electrical appliances.
When all of the installation work is finished, please turn on
the power only after a thorough inspection is performed.
This handbook guarantees succesful system operation.
However, future manuals will contain the latest information.
2. INSTALLATION INFORMATION
Ground the air conditioner.
Do not connect the ground wire to gas or water pipes,
lightning rods, or telephone ground wires. Incomplete
grounding may result in electric shocks.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in
electrical shocks.
Connect the outdoor unit wires before connecting the
indoor unit wires.
You are not permitted to connect the air conditioner with the
power source until the wiring and piping for the air conditioner
is completed.
When following the instructions in this installation
manual, be sure to install drain piping to ensure proper
drainage, and insulate piping in order to prevent
condensation.
Improper or lack of drain piping may result in water leakage
and property damage.
Install the indoor and outdoor units, power supply wiring,
and connecting wires at least 1 meter away from any
televisions or radios, in order to prevent possible image
interference or noise.
Depending on the radio waves, a distance of 1 meter may not
be sufficient enough to eliminate the noise.
This appliance is not intended for use by young children,
or infirm persons, without supervision.
Don't install the air conditioner in the following locations:
Anywhere that contains unsealed petrolatum.
Areas with salt-saturated air (such as near the coast).
Areas with caustic gas (sulfide, for example) existent
in the air (such as near a hot spring).
Areas with fluctuations in incoming power supply (or
unstable power where the voltage fluctuates). This can
happen in some factories where some large machinery
can cause noise ion power lines.
In buses or cabinets.
In kitchens that contain gas or oil.
Areas with electromagnetic waves.
Areas with inflammable gases or other materials.
Anywhere near evaporating acids or alkaline liquids.
Any locations undergoing special delicate conditions.
If the refrigerant leaks during installation, ventilate the
area immediately.
Toxic gas may be produced if the refrigerant comes into
contact, whether direct or indirect, with fire.
Since the temperature of the refrigerant circuit will be
high, please keep the interconnection cable away from
the copper tube.
After completion of all installation work, check that the
refrigerant does not leak.
Toxic gas may be produced if the refrigerant leaks into the
room and comes into contact with a fire source, such as a fan
heater, stove, or cooker.
INSTALLATION ORDER
Select the location
Install the indoor unit
Install the outdoor unit
Install the connecting pipe
Connect the drain pipe
Complete all wiring
Test the system operation
CAUTION
The appliance shall be installed in accordance with
national wiring regulations.
Do not operate your air conditioner in a wet room, such
as a bathroom or laundry room.
An all-pole disconnection device, which has at least 3mm
clearances in all poles, and has a leakage current that
may exceed 10mA, and the residual current device (RCD)
having a rated residual operating current not exceeding
30mA, with disconnection, must be incorporated in the
fixed wiring, in accordance with all relevant wiring laws.