10. WIRING
Link the connective cables to the terminals, as identified with
their respective mached numbers on the terminal block of
indoor and outdoor units.
Re-install the cover or the protection board.
Connect the Cable
10.1
Remove the electric cover of the outdoor unit.
If there is no cover on the outdoor unit, disassemble
the bolts f rom the maintenance board and remove the
protection board. (See Fig. 10.1, 10.2)
Cover
Screw
Fig. 10.1
Fig. 10.2
NOTE:
Remark per EMC Directive 2004/108/EC.
To prevent flicker impressions during the start of the compressor
(technical process), following installation conditions apply:
1. The power connection for the air conditioner has to be done at
the main power distribution. The distribution has to be of a low
impedance, normally the required impedance is reached at a
32A fusing point.
2. No other equipment should be connected with this power line.
3. For detailed installation exceptions, please refer to your power
supplier, to confirm if restrictions apply for products like washing
machines, air conditioners or electrical ovens.
4. For power details of the air conditioner refer to the rating plate
of the product.
5. For any other questions, please contact your local dealer.
The appliance shall be installed in accordance with national
wiring regulations.
The air conditioner should use an independent power
supply with a properly-rated voltage.
The external power supply to the air conditioner should
have ground wiring, which is linked to the ground wiring
of the indoor and outdoor unit.
The wiring work should be done by qualified persons,
and done according to circuit drawing.
An all-pole disconnection device which has at least 3mm
separation distance in all-pole, and a residual current
device (RCD) with a rating of above 10mA, shall be
incorporated in the fixed wiring, according to the national
rules.
Be sure to locate the power wiring and the signal wring
well to avoid cross-disturbance.
Do not turn on the power until you have carefully checked
everything after wiring.
The power cord type designation is H07RN-F.
2) The Outdoor Unit. Check:
a. Whether there are any vibrations or abnormal noises
during operation.
b. Whether the generated wind, noise, or condensation
from the air conditioner create any local disturbances.
c. Whether any of the refrigerant has leaked.
After restarting, a protection feature prevents the air
conditioner from being activated for approximately 3 minutes
after shut off.
CAUTION
1) The Indoor Unit. Check:
a. Whether the switch on the remote controller works well.
b. Whether the buttons on the remote controller work well.
c. Whether the air flow louver moves normally.
d. Whether the room temperature is adjusted well.
e. Whether the indicator lights work normally.
f. Whether the temporary buttons work well.
g. Whether the drainage is normal.
h. Whether there is vibration or abnormal noise during
operation.
I. Whether the air conditioner heats well, in the case of the
HEATING/COOLING type.
4
Set the air conditioner to "COOLING" mode with the remote
controller, and check the following points. If there are any
malfunctions, please resolve it according to the chapter
"Troubleshooting" in the "Owner's Manual".
Test the operation.
11. TEST OPERATION
The test operation must be carried out after the entire
installation has been completed.
Please confirm the following points before the test operation:
2
1
According to the user's requirements, install the remote
controller frame in a place where the remote controller's
signal can reach the indoor unit easily.
3
The power voltage fits the rated voltage of the air
conditioner.
There is no obstacle at the outlet and inlet of the outdoor
and indoor units.
The gas-side and liquid-side stop valves are both opened.
The air conditioner is pre-heated by turning on the power.
The indoor unit and outdoor unit are installed properly.
Tubing and wiring are correctly completed.
The refrigerant pipe system is leakage-checked.
The drainage is unimpeded.
The heating insulation works well.
The ground wiring is connected correctly.
The length of the tubing and the added stow capacity of
the refrigerant have been recorded.