Refrigerant Piping Connection Instructions

 CAUTION

•  The branching pipe must be installed horizontally. 

An angle of more than 10° may cause malfunction.  

• 

DO NOT

 install the connecting pipe until both 

indoor and outdoor units have been installed. 

•  Insulate both the gas and liquid piping to prevent 

water leakage.

Step 1: Cut pipes

When preparing refrigerant pipes, take extra care 
to cut and flare them properly. This will ensure 
efficient operation and minimize the need for future 
maintenance.

1.   Measu re the distance between the indoor and 

outdoor units.  

2.   Using a pipe cutter, cut the pipe a bit longer than 

the measured distance.  

 CAUTION

DO NOT

 deform pipe while cutting.  Be extra careful not   

to damage, dent, or deform the pipe while cutting. This 
will drastically reduce the heating efficiency of the unit.  

1.   Make sure that the pipe is cut at a perfect 90° 

angle. Refer to Fig. 8.1 for examples of bad cuts

Oblique

Rough

Warped

90°

Fig. 8.1

Step 2: Remove burrs.

Burrs can affect the air-tight seal of the refrigerant piping 
connection. They must be completely removed.

1.   Hold the pipe at a downward angle to prevent 

burrs f rom falling into the pipe.

2.   Using a reamer or deburring tool, remove all burrs 

from the cut section of the pipe.

Pipe

Reamer

Pointed down

Fig. 8.2

Step 3: Flare pipe ends

Proper flaring is essential to achieve an airtight seal.

1.   After removing burrs f rom cut pipe, seal the ends 

with PVC  tape to prevent foreign materials from 
entering the pipe.  

 

2.   Sheath the pipe with insulating material.

3.   Place flare nuts on both ends of pipe. Make sure 

they are facing the right direction, because it won’t 
be possible to put them on or change their direction
after flaring. See Fig. 8.3

Flare Nut

Copper Pipe

Fig. 8.3

4.  Remove 

PVC 

tape 

from 

ends 

of 

pipe 

when 

ready 

to 

perform flaring work.

 

 

5.   Clamp flare form on the end of the pipe. The end 

of the pipe must extend beyond the flare form.

Flare Form

Pipe

Fig. 8.4

Содержание YN009GMFI22RPD

Страница 1: ...NOTICE Please read this manual carefully before installing or operating your new air conditioning system Be sure to save this manual for your future reference Installation Manual UAB UYB Series Flex Mount UAB Cooling Only Version UYB Cooling and Heating Version Inverter and Inverter Models 18 000 48 000 BTU hr ...

Страница 2: ...If used as a part of a MULTI Split System please refer to the Installation Operation manuals packed with the multi split outdoor unit ...

Страница 3: ...low For electrical work follow all local and national wiring standards and regulations as well as these installation instructions An independent circuit and single outlet must be used If the electrical circuit capacity is insufficient or there is a defect in the electrical work it will cause electrical shock fire Use the specified cable and connect tightly and clamp the cable so that no external f...

Страница 4: ...ended for use by young children or infirm persons without supervision Don t install the air conditioner in the following locations Anywhere that contains unsealed petrolatum Areas with salt saturated air such as near the coast Areas with caustic gas sulfide for example existent in the air such as near a hot spring Areas with fluctuations in incoming power supply or unstable power where the voltage...

Страница 5: ... some spare items please store them carefully aside QUANTITY SHAPE NAME 5 Owner s Manual 6 Installation Manual 7 Remote Controller Manual 1 Remote Controller on some models 2 Remote Controller Holder on some models 4 Alkaline Dry Batteries AM4 1 1 2 2 1 1 Remote Controller Its Holder Others 3 Mounting Screw ST2 9 10 C H 1 ...

Страница 6: ... the unit take into account the following Fragile handle the unit with care Keep the unit upright in order to avoid compressor damage Pre determine the path along which the unit is to be brought in Move and carry this unit without changing its original packaging position by as much as possible When lifting the unit always use protectors to prevent belt damage and pay special attention to the posit...

Страница 7: ...on Inlaying or embedding the screw bolts Install the hanging hook with expanding bolt into the concrete 45 50mm deep to prevent loosening Remove the side board and the grille Refer to Fig 5 8 Side Board Grille Hanging Arm Hanging Screw Bolt 20mm 3 4 In Unit Dimensions 5 3 Table 5 1 unit mm Fig 5 10 Fig 5 11 Fig 5 12 D Connecting Point of Refrigerant Pipe D Gas Side Drain point Downward declivity b...

Страница 8: ...door and indoor unit must not exceed the maximum allowable pipe length If possible DO NOT install the unit where it will be exposed to direct sunshine If possible make sure the unit is located far away from your neighbors property so that the noise from the unit will not cause a disturbance for them If the location is exposed to strong winds for example near a seaside the unit must be placed again...

Страница 9: ...sions W x H x D Mounting Dimensions Distance A Distance B 770x555x300 30 3x21 9x11 8 549 21 6 325 12 8 946x810x410 37 24x31 9x16 14 673 26 5 403 15 87 952x1333x415 37 5x52 5x16 34 634 24 96 404 15 9 845x702x363 33 27x27 6x14 3 540 21 26 350 13 8 800x554x333 31 5x21 8x13 1 514 20 24 340 13 39 YN048GMFI17RUD YN036GMFI17RUD 946x810x410 37 24x31 9x16 14 673 26 5 403 15 87 YN024GMFI22RPD YN018GMFI22RPD...

Страница 10: ... the protective wall cuff inside the hole This protects the edges of the hole and will help seal it when you finish the installation process NOTE The minimum distance between the outdoor unit and walls described in the installation guide does not apply to airtight rooms Be sure to keep the unit unobstructed in at least two of the three vectors M N P See Fig 6 10 CAUTION The drain pipe of the indoo...

Страница 11: ...Pipe Length and Elevation Ensure that the length of the refrigerant pipe the number of bends and the drop height between the indoor and outdoor units meets the requirements shown inTable 8 1 Table 8 1 The Maximum Length And Drop Height Based on Models Unit m ft Type of Model Capacity Btu hr Length of piping Maximum drop height 50Hz T1 Condition R22 Split Type 12K 15 49 8 26 18K 24K 30 98 4 10 32 8...

Страница 12: ... perfect 90 angle Refer to Fig 8 1 for examples of bad cuts Oblique Rough Warped 90 Fig 8 1 Step 2 Remove burrs Burrs can affect the air tight seal of the refrigerant piping connection They must be completely removed 1 Hold the pipe at a downward angle to prevent burrs from falling into the pipe 2 Using a reamer or deburring tool remove all burrs from the cut section of the pipe Pipe Reamer Pointe...

Страница 13: ... to tighten the flare nut according to the torque values in table 8 2 NOTE Use both a spanner and a torque wrench when connecting or disconnecting pipes to from the unit Fig 8 7 CAUTION Be sure to wrap insulation around the piping Direct contact with the bare piping mayresult in burns or frostbite Make sure the pipe is properly connected Over tightening may damage the bell mouth and under tightenin...

Страница 14: ... and LIQUID Valves 1 Connect the blue low side hose of the manifold gauge to service port on the outdoor unit s GAS SIDE valve use a 1 4 to 5 16 port adapter if needed which is sold separately 2 Connect yellow middle or common hose from the manifold gauge to the vacuum pump MC MC Fig 6 1 Air and foreign matter in the refrigerant circuit BLUE Low Pressure Side of Manifold Gauge RED High Pressure Si...

Страница 15: ...th the LIQUID side and GAS side Service Calves 13 Tighten valve caps on all three valves service port Liquid Side Gas Side by hand Then tighten it further using a torque wrench if needed OPEN VALVE STEMS GENTLY When opening valve stems turn the hexagonal wrench until it seats against the stopper Do not try to force the valve to open further Note on Adding Refrigerant ADDITIONAL REFRIGERANT PER PIP...

Страница 16: ... on the power until you have carefully checked everything after wiring The power cord type designation is H07RN F 2 The Outdoor Unit Check a Whether there are any vibrations or abnormal noises during operation b Whether the generated wind noise or condensation from the air conditioner create any local disturbances c Whether any of the refrigerant has leaked After restarting a protection feature pr...

Страница 17: ...15 installation manual ...

Страница 18: ...ales agency or manufacturer for details 16122700000004 20171209 is a registered trademark of Parker Davis HVAC International Inc Parker Davis HVAC International Inc 2250 NW 102 Place Doral FL 33172 USA Tel 305 513 4488 Fax 305 513 4499 email info pd hvac com Website www pd hvac com Copyright 2017 Parker Davis HVAC International Inc All rights reserved ...

Отзывы: