• Description on power-down
Data
Power-down Point
0
No power-down
1
Not used
2
Panel-POWER SUPPLY
3
SCAN
4
SCN-5V
5
Y-DRIVE
6
Y-DCDC
7
Y-SUS
8
ADR
9
X-DRIVE
A
X-DCDC
B
X-SUS
C
DIG-DCDC
D
IC4
E
Reservation
F
Power-down point unidentified
GPW: Obtaining panel white-balance adjustment values
Note: Ignore the 2-byte checksum at the end.
Order
Data
Size
Remarks
1
W/B table currently used
3 bytes
PT1 - PT3 (*)
2
Main contrast
4 bytes
0000 - 0511
3
Red contrast of W/B adjustment value
4 bytes
0000 - 0511
4
Green contrast of W/B adjustment value
4 bytes
0000 - 0511
5
Blue contrast of W/B adjustment value
4 bytes
0000 - 0511
6
Main brightness
4 bytes
0000 - 1023
7
Red brightness of W/B adjustment value
4 bytes
0000 - 1023
8
Green brightness of W/B adjustment value
4 bytes
0000 - 1023
9
Blue brightness of W/B adjustment value
4 bytes
0000 - 1023
(Reference) GS2: Obtaining information on the status of the unit
Notes: • Ignore the 2-byte checksum at the end.
• The data expected to be used for service may be "5. Data on temperature" and "15,16. Hour meter".
(
∗
1) Each time hour-meter data are cleared, the accumulated time data are updated. The total for data items 15 and 16 is the total
power-on time after shipment. The accumulated time of cleared hour-meter data cannot be cleared.
(
∗
2) The hour-meter data that indicate driving hours of the panel are displayed on the Factory menu. Upon shipment, the data are
cleared.
Order
Data
Size
Remarks
1
Notifying that the unit is shifting to Standby mode
1 byte
1: OK for shifting to Standby
2
Whether or not the main unit has been adjusted
1 byte
0: Adjusted, 1: Not adjusted
3
With/without backup for adjustment values
1 byte
0: With backup, 1: Without backup
4
Data on power-down
2 bytes 1st byte: 1st PD, 2nd byte: 2nd PD
5
Data on temperature (TEMP1)
3 bytes
000 - 255
6
Abnormality in RST2 (power decrease of DC-DC converter)
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
7
IC4 communication failure
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
8
EEPROM communication failure
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
9
Audio failure
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
10
Volume IC communication failure
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
11
Backup ROM communication failure
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
12
Data on temperature (TEMP1) not obtained
1 byte
0: Normal, 1: SD process completed, 2: In the process of SD warning
13
Operational status of panel protection mechanism
1 byte
0: Protection mechanism not activated, 1: Protection mechanism activated
14
Reservation
2 bytes
∗∗
15
Accumulated time of cleared hour-meter (
∗
1)
7 bytes 1st-5th byte: Hour, 6th-7th byte: Minute
16
Hour-meter (clearable) (
∗
2)
7 bytes 1st-5th byte: Hour, 6th-7th byte: Minute
Data
Table
PT1
W/B table for NTSC
PT2
PT3
Reserved table
Not used (W/B table for PAL)
(*)