GNG: Returning the data (logs) on power-down and shutdown of the MR side [SD2]
• Details on the NG data
Order
Data
Size
1
Latest NG data
1 byte
2
Data of subcategory for the latest NG
1 byte
3
Data of MR hour meter for the latest NG
7 bytes
4
Data on temperature for the latest NG (TEMP2)
3 bytes
5
Second latest NG data
1 byte
6
Data of subcategory for the second latest NG
1 byte
7
Data of MR hour meter for the second latest NG
7 bytes
8
Data on temperature for the second latest NG (TEMP2)
3 bytes
9
Third latest NG data
1 byte
10
Data of subcategory for the third latest NG
1 byte
11
Data of MR hour meter for the third latest NG
7 bytes
12
Data on temperature for the third latest NG (TEMP2)
3 bytes
13
Fourth latest NG data
1 byte
14
Data of subcategory for the fourth latest NG
1 byte
15
Data of MR hour meter for the fourth latest NG
7 bytes
16
Data on temperature for the fourth latest NG (TEMP2)
3 bytes
Order
Data
Size
17
Fifth latest NG data
1 byte
18
Data of subcategory for the fifth latest NG
1 byte
19
Data of MR hour meter for the fifth latest NG
7 bytes
20
Data on temperature for the fifth latest NG (TEMP2)
3 bytes
21
Sixth latest NG data
1 byte
22
Data of subcategory for the sixth latest NG
1 byte
23
Data of MR hour meter for the sixth latest NG
7 bytes
24
Data on temperature for the sixth latest NG (TEMP2)
3 bytes
25
Seventh latest NG data
1 byte
26
Data of subcategory for the seventh latest NG
1 byte
27
Data of MR hour meter for the seventh latest NG
7 bytes
28
Data on temperature for the seventh latest NG (TEMP2)
3 bytes
29
Eighth latest NG data
1 byte
30
Data of subcategory for the eighth latest NG
1 byte
31
Data of MR hour meter for the eighth latest NG
7 bytes
32
Data on temperature for the eighth latest NG (TEMP2)
3 bytes
• Data on the subcategories for failure in 3-wire serial
communication of the main microcomputer
Data
Cause of Shutdown
0
No subcategory
1
Communication failure of the IF microcomputer
2
IC2 communication failure
3
IC3 communication failure
• Data on the subcategories for failure in the digital tuner
Data
Cause of Shutdown
0
No subcategory (DTV for North America)
1
Communication failure of the DTV microcomputer
(PS/RST)
2
DTV NG (DEVICE)
3
DTV microcomputer (CMD)
4
DTV microcomputer communication (RETRY)
5
Not used [PC CARD Communication NG (CD-COM)]
6
Not used [PC CARD Mdule (CD-DEV)]
7
Not used [PC CARD Reset NG (CD-RST)]
Data
Cause of Shutdown
0
No abnormality
1
Power-down of the MR power supply
2
Communication failure of the module microcomputer
3
Three-wire serial communication failure of the main
microcomputer
4
IIC communication failure of the main microcomputer
5
Communication failure of the main microcomputer
6
Having abnormally high temperature (TEMP2)
7
Fan stopped
8
Failure of the UART communication
9
Abnormality in RST2 (Main microcomputer)
(power decrease of DC-DC converter)
• Data on the subcategories for failure in IIC
communication of the main microcomputer
Data
Cause of Shutdown
0
No subcategory
1
EEPROM (128k) (IC7205)
2
Not used (GCR)
3
IC1 main (IC6107)
4
IC1 sub (IC6255)
5
AD-PLL main (IC6402)
6
AD-PLL sub (IC6602)
7
IC6 (IC6951)
8
Not used (HDMI1)
9
HDMI2(IC6881)
A
7-3VIDEO SW (IC8002)
B
6-2RGB SW (IC8005)
C
Front end 1 (U7501)
D
Front end 2 (U7502)
E
CC UCOM (IC8903)
F
PANEL LINK TX (IC7401)
G
PANEL LINK RX (IC4202)
H
Not used
I
Not used
K
AV-EEP ROM