PDP-5050SX
121
5
6
7
8
5
6
7
8
C
D
F
A
B
E
GPD: Obtaining power-down-point log on the panel
Order
Data
Size
Remarks
1
Latest "1st PD" data
1 byte
0-D or F
2
Latest "2nd PD" data
1 byte
0-D or F
3
Data of hour meter for the latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
4
Data on temperature for the latest PD (TEMP1)
3 bytes
000 - 255
5
Second latest "1st PD" data
1 byte
0-D or F
6
Second latest "2nd PD" data
1 byte
0-D or F
7
Data of hour meter for the second latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
8
Data on temperature for the second latest PD (TEMP1)
3 bytes
000 - 255
9
Third latest "1st PD" data
1 byte
0-D or F
10
Third latest "2nd PD" data
1 byte
0-D or F
11
Data of hour meter for the third latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
12
Data on temperature for the third latest PD (TEMP1)
3 bytes
000 - 255
13
Fourth latest "1st PD" data
1 byte
0-D or F
14
Fourth latest "2nd PD" data
1 byte
0-D or F
15
Data of hour meter for the fourth latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
16
Data on temperature for the fourth latest PD (TEMP1)
3 bytes
000 - 255
17
Fifth latest "1st PD" data
1 byte
0-D or F
18
Fifth latest "2nd PD" data
1 byte
0-D or F
19
Data of hour meter for the fifth latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
20
Data on temperature for the fifth latest PD (TEMP1)
3 bytes
000 - 255
21
Sixth latest "1st PD" data
1 byte
0-D or F
22
Sixth latest "2nd PD" data
1 byte
0-D or F
23
Data of hour meter for the sixth latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
24
Data on temperature for the sixth latest PD (TEMP1)
3 bytes
000 - 255
25
Seventh latest "1st PD" data
1 byte
0-D or F
26
Seventh latest "2nd PD" data
1 byte
0-D or F
27
Data of hour meter for the seventh latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
28
Data on temperature for the seventh latest PD (TEMP1)
3 bytes
000 - 255
29
Eighth latest "1st PD" data
1 byte
0-D or F
30
Eighth latest "2nd PD" data
1 byte
0-D or F
31
Data of hour meter for the eighth latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
32
Data on temperature for the eighth latest PD (TEMP1)
3 bytes
000 - 255
Notes: • Ignore the 2-byte checksum at the end.
• For details, see "Description on power-down."
Содержание PDP4350SX
Страница 9: ...PDP 5050SX 9 5 6 7 8 5 6 7 8 C D F A B E ...