78
RS-232C Adjustment Mode
57. PLUG and PLAY
Function
The external control apparatus switches the EDID setting
of the plasma display.
Transmit Data
DFH
80H
60H
8EH
01H
DATA00
CKS
DATA00
01H : PC
02H : STB/DVD (HDCP signal)
ACK
The plasma display returns the following ACK.
7FH
60H
80H
8EH
01H
DATA00
CKS
DATA00
01H : PC
02H : STB/DVD (HDCP signal)
58. BLACK LEVEL SELECT
Function
The external control apparatus switches the signal level
setting of the plasma display.
Transmit Data
DFH
80H
60H
8FH
01H
DATA00
CKS
DATA00
01H : low
02H : high
ACK
The plasma display returns the following ACK.
7FH
60H
80H
8FH
01H
DATA00
CKS
DATA00
01H : low
02H : high
59. OSM CONTRAST SELECT
Function
The external control apparatus switches the OSM contrast
level setting of the plasma display.
Transmit Data
DFH
80H
60H
37H
01H
DATA00
CKS
DATA00
01H : normal
02H : low
ACK
DFH
80H
60H
37H
01H
DATA00
CKS
DATA00
01H : normal
02H : low
60. OSM Select
Function
The external control apparatus turns the screen display
(OSD) of the display on and off.
Transmit Data
DFH
80H
60H
58H
01H
DATA00
CKS
DATA00
01H : OSD ON
02H : OSD OFF
ACK
DFH
80H
60H
58H
01H
DATA00
CKS
DATA00
01H : OSD ON
02H : OSD OFF
It operates as shown on the following table.
Coordinates/displays
menu items
Displays sound volume,
input, and screen size
Operation
When operating with
a remote control
When operated
by PC control
OSD display
When OSD
is on
When OSD
is off
When OSD
is on
When OSD
is off
Yes
No
No
Yes
No
Yes
Yes
No
61. INVERSE Set
Function
The external control apparatus sets INVERSE, WHITE of
the plasma display.
Transmit Data
DFH
80H 60H
C7H 03H
DATA00 DATA01
DATA02 CKS
DATA00 : INVERSE (reverse)/WHITE
00H : no change
01H : on (INVERSE)
02H : off
03H : white
DATA01 : WORKING TIME
00H : on
(display setting)
01H : 03M (minutes)
02H : 06M (minutes)
:
FFH : 12H (hours) 45M (minutes)
DATA02 : WAITING TIME (interval)
01H : 03M (minutes)
02H : 06M (minutes)
:
FFH : 12H (hours) 45M (minutes)
ACK
3FH
60H
80H
C7H
00H
CKS
* Display setting, waiting time can be set in 3-minute units.
Example: 03H = 9 minutes, 1EH = 1 hour, 30 minutes