70
RS-232C Adjustment Mode
27. PHASE Gain Data
Function
The external control apparatus changes the PHASE Gain
Data (phase) of the display.
Transmit Data
DFH
80H 60H 7FH 03H
DATA00
DATA01
DATA02
CKS
DATA00 : USER PICTURE Gain Flag
03H
DATA01 : PHASE Gain Flag
03H
DATA02 : PHASE Gain
00H : 0
:
40H : +64
ACK
7FH
60H
80H
7FH
02H
DATA00
DATA01
CKS
DATA00 : USER PICTURE Gain Flag
03H
DATA01 : PHASE Gain Flag
03H
28. CLOCK Gain Data
Function
The external control apparatus changes the CLOCK Gain
Data (frequency ratio) of the display.
Transmit Data
DFH
80H 60H 7FH 03H
DATA00
DATA01
DATA02
CKS
DATA00 : USER PICTURE Gain Flag
03H
DATA01 : CLOCK Gain Flag
04H
DATA02 : CLOCK Gain
C0H : -64
:
FFH : -01
00H : 0
01H : +01
:
40H : +64
ACK
7FH
60H
80H
7FH
02H
DATA00
DATA01
CKS
DATA00 : USER PICTURE Gain Flag
03H
DATA01 : CLOCK Gain Flag
04H
29. OSM ADJ. POSITION Data
Function
The external control apparatus switches the Menu Position
of the display.
Transmit Data
7FH
60H
80H
1AH
02H
DATA00
DATA01
CKS
DATA00 : OSM ADJ. Gain Flag 02H
DATA01
01H : 1 (upper left)
02H : 2 (upper center)
03H : 3 (upper right)
04H : 4 (lower left)
05H : 5 (lower center)
06H : 6 (lower right)
ACK
7FH
60H
80H
1AH
01H
DATA00
CKS
DATA00 : OSM ADJ. Gain Flag 02H
30. POWER MGT Select
Function
The external control apparatus turns POWER MGT of the
display on and off.
Transmit Data
DFH
80H
60H
1AH
02H
DATA00
DATA01
CKS
DATA00 : POWER MGT Select 03H
DATA01
01H : on
02H : off
ACK
DFH
80H
60H
1AH
02H
DATA00
DATA01
CKS
DATA00 : POWER MGT Select 03H
DATA01
01H : on
02H : off
31. SIDE MASK Set
Function
The external control apparatus sets the SIDE MASK level
of the display.
Transmit Data
DFH
80H
60H
C6H
01H
DATA00
CKS
DATA00 : SIDE MASK
00H : 0
:
0FH : 15
ACK
DFH
80H
60H
C6H
01H
DATA00
CKS
DATA00 : SIDE MASK
00H : 0
:
0FH : 15