Methods of Securing: Basic methods of securing are shown right. Avoid blocking or covering
areas aside from those indicated by
. Before attaching the unit
to fittings, double-check that the thickness and height of the fittings,
and the number of fixing bolts is correct. (Also refer to 2.4.1
“Mounting to fittings (pg. 21)”.)
Special Installation (Place product upright and flush into wall (embedding in the wall))
X
(Front of the unit)
<Viewed from Above>
<Viewed from the Right Side>
✩
Operating Temperature Restrictions
Temperature in space X and Y
A: 0 to 300 mm
0 to 40 °C
Y
(Rear of the unit)
2.4.6 Place product upright and flush into wall (embedding in the wall)
Carefully read the following before trying to embed the unit in a wall, and make sure to observe all the limitations specified
below.
Be sure to mount the unit so that twisting, bending, or other deformation of the unit does not exceed 4 mm.
(1) Embedding in walls with space provided behind the unit (with no obstructions within a distance of 300mm from
the back surface of the unit).
A
A
A
A