The log of the past eight shutdowns is displayed. Shutdown points and the hour meter value when the shutdown was generated are
displayed, with the latest shutdown data at the top.
The meanings of indications for shutdown points are shown in the table below.
No.
Type of Shutdown
On-Screen Display
(MAIN)
Subcategory
1
Abnormality in IC4 communication
IC4
2
Abnormality in module microcomputer IIC
communication
MD-IIC
Exists.
3
DIGITAL-DCDC power decrease
RST2
4
Abnormality in panel temperature
TEMP1
5
Short-circuiting of the speakers
AUDIO
6
Abnormality in module microcomputer communication
MODULE
7
Abnormality in three-wire serial communication of the
main microcomputer
MA-SRL
Exists.
Exists.
8
Abnormality in main microcomputer IIC communication
MA-IIC
9
Abnormality in main microcomputer communication
MAIN
10
FAN stopped
FAN
11
Abnormality in unit temperature
TEMP
12
Abnormality in the ASIC power on the main
microcomputer side
M-DCDC
Exists.
Exists.
13
Other failures
ETC
No.
Type of Shutdown
Subcategory
2
MD-IIC
EEPROM4K, EROM2K
7
MA-SRL
IF microcomputer, IC2, IC3
8
MA-IIC
MA-EEP, IC1-V, IC1-Y, AD-M, AD-S, SL-EEP, IC6/1, IC6/2, VOLIC
11
TEMP
INSIDE/AIR (INSIDE = TEMP2/AIR =TEMP3)
13
ETC
RLS, VCC-D1, VCC-D2
• Panel shutdown information