43
[507CMX]
Special Installation (Ceiling suspension with wires)
When suspending from a ceiling with wire, use the brackets shown below to prevent concentrating loads on the upper
two fixing points.
For additional safety, secure the wires to separate fittings or parts of the ceiling.
Use mounting screws of material stronger than soft steel and use hexagonal bolts.
Use wires adequate for the combined weight of the panel and the weight of the support brackets.
No!
When installing the Plasma Display, DO NOT use the handles as means of hanging the display.
3.5.5 Ceiling suspension (with wires)
When suspending with wire, attach the unit either at rows A and B or at rows C and D to keep it from warping. In
addition, the unit must be attached at four or more points, with these points distributed symmetrically on opposite
sides of the vertical and horizontal center lines.
✩
Operating environment for standard installation
• Ambient Temperature: 0 °C to 40 °C
✩
Operating environment for vertical installation
(*1)
• Ambient Temperature: 0 °C to 40 °C
✩
Operating temperatures for Upside-Down Installations
(*1, *2)
• Ambient Temperature: 0 °C to 35 °C
*1
For this installation, set the ‘FAN CONTROL’ to ‘MAX’ as shown in “5.4.3 Adjustment and Setting in the Integrator Mode 14)
Cooling Fan Control Setting” (pg. 235).
*2
When INPUT2 has been selected, use input compatible signal up to 1280x1024 (60 Hz) at ambient temperature condition of 0 °C
to 35 °C.
Attach so that the fan is on the left
side when viewed from the rear.
C
C
D
D
B
A
A
B
Wires
Brackets
Screws
Wires
Brackets
Screws