DRM-6NX
36
1
4
CN13
1: VD5V
2: REMI
3: REMO
4: GNDD
CN13
MAIN BOARD ASSY
RU-V101
1
1
2
2
3
3
4
Q1
10k
2.2k
Q1: DTC124ES or UN4212
3P mini jack
Interface
PH type
connector
(4P)
V +5V
REMI
GND
SERVICE REMOTE CONTROLLER
6.2.1 HOW TO START/CANCEL TEST MODE
6.2 ADJUSTMENT
÷
Test Mode
Shows the function table of the remote controller (RU-V101) for service as follows. When operating the CD-ROM directly,
it is possible to operate as shown below by connecting the wired-remote control to the CD-ROM with the interface.
FUNCTION TABLE OF THE REMOTE CONTROLLER (RU-V101) FOR SERVICE
÷
Schematic Diagram of the Conversion Jig for Remote Control Operation
TEST MODE : ON
REAR PANEL
(IDSB BOARD ASSY)
REAR PANEL
(IDSB BOARD ASSY)
REAR PANEL
(IDSB BOARD ASSY)
ON
1 2
3
FUNCTION SW (S1001)
ID SW (S954)
TEST MODE/ON
TERM/ON
SW POSITION: 1 to 7
0
2
6
4
7
1
5
3
ID SW (S954)
SW POSITION: 0 only
0
2
6
4
7
1
5
3
TEST MODE 1
TEST MODE 2
Power Switch: ON
Power Switch: OFF