DRM-6NX
51
Details of Error
Q1.
The Status LED continues to flash (5 minutes
or more) and never stops.
Q2.
How can I reset to the factory default settings?
Q3.
The firmware version can not be upgraded.
Q4.
Connection is possible with ping and ftp, but
opening with a Web Browser is not possible.
Q5.
Ping passes, but connection by ftp or web
browser is not possible.
Q6.
Changing of the IP address is not possible with
arp and ping Command.
Q7.
The network computer does not see the DRM-
6NX.
Q8.
At the time of access by a network computer,
a password is demanded immediately, but
access is not possible, no matter what is
entered.
Troubleshooting Know-how Collection
Measure
A1.
Check that the SCSI Termination switch on the rear
of the DRM-6NX is ON. If this does not help, reset to
the factory default settings.
A2.
Resetting to the factory default settings can be done
as described below.
1. Hold the Reset button pressed while switching
the power to the DRM-6NX ON, and keep it
pressed until all three LEDs flash at the same
time. At this time, release the Reset button once,
and press it again after waiting for about 5 sec.
When the Status LED and the Network LED have
lit and gone out, switch off the power to the DRM-
6NX and then restart it.
2. Connect with a web browser, enter Administration,
and press the Factory Default button.
3. Log in at the DOS prompt with ftp 192.36.253.80
(IP address). (The User Name is root and the
Password is pass.) Enter "get defaults" to obtain
the Factory Default settings.
A3.
Enter FLASH in capital letters When you issue "put"
command at ftp command line.
A4.
Has the Status LED stopped flashing? The DRM-6NX
is ready when the Status LED has stopped flashing.
If the LED has not stopped flashing, wait for about 5
minutes. If it still does not stop flashing, refer to Q1.
A5.
Restart the DRM-6NX once and start again from IP
address setting. Changing of the IP address with arp
and ping command is possible only within 30 minutes
after start of the DRM-6NX.
A6.
Changing of the IP address with arp and ping command
is possible only within 30 minutes after start of the
DRM-6NX. Restart the DRM-6NX once and start
again from IP address setting.
A7.
In the default settings The DRM-6NX can be seen
only when the workgroup of the client PC is
"workgroup". Even when it is "workgroup", it can not
be seen for some time after start. Even when it can
not be seen, the search function in the start menu of
the computer can be used to search for it. In the
default settings. The computer name of the DRM-
6NX is pioneer ****** (****** stands for the last six
digits of the serial number).
A8.
This condition can occur when resetting to the factory
default settings has not been done after a change of
the firmware. Reset once to the factory default
settings. Refer to Q2.