MANOCOMB®-IP65 Operating Instructions
7e. pneumatic connection
7f. pneumatic data
The MANOCOMB pressure switch is equipped with 1 or 2 pneumatic limit swit-
ches (3/2-way valves).
Connect the supply air to the inlet 1 (for 1K and 2K versions) as well as the
control air a to outlet 2 (control air b to outlet 4 - only 2K version).
All connections are located at the bottom of the MANOCOMB pressure switch.
The switching function is guaranteed if the supply air pressure is at least 2 bar
and a maximum of 8 bar. The MANOCOMB pressure switch is calibrated at 4
bar supply air by factory default.
Set your supply air to 4 bar +/- 0.1 bar for optimum function values in terms of
switching behavior and switching or switch-back accuracy.
P
process connection
1
supply air inlet
2
control air outlet a
4
control air outlet b
1
Remarks
1
control air outlet b only for 2K models
description
3/2-way poppet valve, open centre between actuations, servo
controlled
switching function
normally open or normally closed
supply air pressure
2 - 8 bar (4 bar recommended)
supply media
5 µm, lubricated or filtered non-lubricated compressed air or
any other according to ISO-VG 10
consumption
approx. 0,7 l/min
Содержание MANOCOMB-IP65
Страница 1: ...Bedienungsanleitung Operating Instructions MANOCOMB IP65 MANOCOMB IP65 CV MANOCOMB IP65 PN ...
Страница 2: ...MANOCOMB IP65 Bedienungs und Wartungsanleitung ...
Страница 27: ...DEUTSCH ENGLISH 27 MANOCOMB IP65 Bedienungs und Wartungsanleitung ...
Страница 28: ...MANOCOMB IP65 Operating Instructions ...
Страница 45: ...DEUTSCH ENGLISH 45 MANOCOMB IP65 Operating Instructions 6g Dimensions MANOCOMB IP65 CV Standard version 1K 1KA ...
Страница 53: ...DEUTSCH ENGLISH 53 MANOCOMB IP65 Operating Instructions ...
Страница 54: ...MANOCOMB IP65 Operating Instructions ...
Страница 55: ...DEUTSCH ENGLISH 55 MANOCOMB IP65 Operating Instructions ...