background image

6

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2021 Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

Fueling The Heater:

Kerosene (K-1)

For optimal performance of this heater, it is 

strongly suggested that K-1 kerosene be used, 

especially in temperatures lower than 26°F 

(-3°C). K-1 kerosene has been refined to virtually 

eliminate contaminants, such as sulfur, which can 

cause a rotten egg odor during the operation of 

the heater. Using diesel fuel can cause excess 

soot production. Do not use Bio-Diesel as this fuel 

will damage your heater’s seals and filter.

 - CSA certified for use with K-1 kerosene, no. 

1 & no. 2 diesel, JP8/Jet A Fuel, no. 1 and no. 

2 fuel oil.

DO NOT use any fuel that is not approved above.

 - NEVER use fuel such as, benzene, alcohol, white 

glass, camp stove fuel, paint thinners, or other oil 

compounds in this heater. THESE ARE VOLATILE 

FUELS THAT CAN CAUSE A FIRE OR 

EXPLOSION.

- NEVER store kerosene in the living space. Kerosene 

should be stored in a well ventilated area outside 

the living area.

 - NEVER store kerosene in direct sunlight or near a 

source of heat.

 - NEVER use kerosene that has been stored from 

one season to the next. Kerosene deteriorates 

over time. OLD KEROSENE WILL NOT BURN 

PROPERLY IN THIS HEATER. 

NOTE: Kerosene should only be stored in a blue 

container that is clearly marked “Kerosene.” Never 

store kerosene in a red container. Red is associated 

with gasoline.

Ventilation:

 - Risk of indoor air pollution and Carbon 

Monoxide Poisoning. Use heater only in well 

ventilated areas.

 - Refer to Safety Information on page 3 for 

information about Carbon Monoxide 

Poisoning.

 - ALWAYS

 provide a fresh air opening in the heated space 

of at least three square feet (2,800 sq. cm) for each 

100,000 Btu / Hr. (29 kW) of heater output. Provide a 

larger opening if more heaters are being used.

 

Minimum Ventilation Opening Needed

45-KFA

80T-KFA

140T-KFA

1.4 ft.²

2.4 ft.²

4.2 ft.²

1300 cm²

2230 cm²

3902 cm²

Minimum Ventilation Opening Needed

175T-KFA

215T-KFA

5.3 ft.²

6.5 ft.²

4924 cm²

6039 cm²

OPERATION

NEVER FILL 

THE FUEL TANK 

INDOORS. AL-

WAYS FILL THE TANK OUTDOORS. BE 

SURE THAT THE HEATER IS ON LEVEL 

GROUND WHEN FUELING, AND NEVER 

OVERFILL THE TANK.

CAUTION

CARBON MONOXIDE POISONING MAY 

LEAD TO DEATH!

DANGER

DO NOT USE 

GASOLINE OR 

CRANKCASE 

DRAININGS.

 

WARNING

NEVER REFUEL 

THIS HEATER 

WHILE IT IS HOT 

OR OPERATING. FIRE OR EXPLOSION 

COULD RESULT.

 

DANGER

Содержание REMINGTON REM-140T-KFA-B

Страница 1: ...N THIS HEATER IS SUITABLE FOR OUTDOOR USE AND INDOOR USE ONLY IN WELL VENTILATED AREAS INDOOR USE PERMITTED ONLY FOR THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTR...

Страница 2: ...ED DO NOT START THE HEATER WHEN THE CHAMBER IS HOT WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from t...

Страница 3: ...D COMBUSTIBLES AWAY FROM HEATER WARNING The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heat...

Страница 4: ...ging materials from the shipping carton Note Save the box and packaging materials for future storage Shown With Optional Cord Wraps Cord Wraps Optional Carry Handle 1 10 mm Screws 2 15 mm Screws 2 WHA...

Страница 5: ...secure before operating the heater SPECIFICATIONS Model 45 KFA 80T KFA 140T KFA 175T KFA 215T KFA Rating Btu Hr kW 45 000 13 2 80 000 23 4 140 000 41 175 000 51 3 215 000 63 Fuel Consumption Gal Hr L...

Страница 6: ...ight or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene shoul...

Страница 7: ...o not have a room temperature display feature The room temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F...

Страница 8: ...re starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fu...

Страница 9: ...rating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 0 21 BAR 80T KFA 4 2 PSI 0 29 BAR...

Страница 10: ...2021 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual WIRING DIAGRAMS 80T KFA 140T KFA 175T KFA 190T KFA 215T KFA Models 140T 175T 190T 215T KFA have a digital display 80T K...

Страница 11: ...mproper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh keros...

Страница 12: ...A POWER SOURCE 2021 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual EXPLODED VIEW 45 KFA 80T KFA Only 140T KFA 215T KFA Only 13 10 12 8 11 9 29 25 3 15 2 4 6 1 7 21 23 16 17...

Страница 13: ...dy 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 18 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020 010...

Страница 14: ...aid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other exp...

Страница 15: ...e ces instructions devraient utiliser ou entretenir cette chaufferette Pour obtenir plus de renseignements manuel d utilisation tiquettes etc contacter Pinnacle Climate Technologies au 800 641 6996 DA...

Страница 16: ...A CHAUFFER ETTE LORSQUE LA CHAMBRE DE COMBUSTION EST CHAUDE RISQUE D INCENDIE DE BR LURE D INHALATION ET D EXPLOSION Garder les mat riaux combustibles tels que mat riaux de construction papier ou cart...

Страница 17: ...emanuelsontdes chaufferettes feudirectet airpuls aliment esau k ros ne Leschaufferettes airforc auk ros nesont principalementdestin esauchauffagetemporairedes b timentsencoursdeconstruction demodifica...

Страница 18: ...carton Remarque Conserver la bo te et les mat riaux d emballage pour y ranger ult rieurement la chaufferette Illustr avec enrouleurs de cordon en option Enrouleurs de cordon en option Poign e 1 Vis d...

Страница 19: ...5T KFA 215T KFA SP CIFICATIONS Mod les n 45 KFA 80T KFA 140T KFA 175T KFA 215T KFA Classement Btu h kWh 45 000 13 2 80 000 23 4 140 000 41 175 000 51 3 215 000 63 Consommation de carburant L h 1 32 2...

Страница 20: ...t d une source de chaleur NE JAMAIS utiliser du k ros ne entrepos la saison pr c dente pour la saison suivante Le k ros ne se d t riore avec le temps LE VIEUX K ROS NE NE BR LE PAS CORRECTEMENT DANS C...

Страница 21: ...ce L afficheur de temp rature ambiante affiche LO Bas lorsque la temp rature ambiante est inf rieure 18 C HI lev e lorsque la temp rature ambiante est sup rieure 37 C Entre 18 C et 37 C l afficheur in...

Страница 22: ...e carburant doit tre nettoy au moins deux fois par saison de chauffage Nettoyer le filtre en le rin ant dans du k ros ne K 1 propre Nettoyer le filtre imm diatement en cas de carburant contamin FILTRE...

Страница 23: ...fonctionne tourner la vis de r glage de la pompe dans le sens horaire pour augmenter la pression et dans le sens antihoraire pour diminuer la pression Pression correcte de la pompe Num ro de mod le Pr...

Страница 24: ...rique 80T KFA 140T KFA 175T KFA 190T KFA NOIR NOIR CELLULE PHOTO LECTRIQUE NOIR NOIR CAPTEUR DE TEMP RATURE AMBIANTE NOIR NOIR FICHE LECTRIQUE JAUNE BLANC VERT LIMITEUR INTERRUPTEUR D ALIMENTATION 120...

Страница 25: ...Jeu incorrect du rotor 1 Remplir le r servoir de k ros ne neuf 2 V rifier la pression de la pompe 3 Nettoyer remplacer la bougie 4 Nettoyer remplacer le filtre carburant 5 Nettoyer remplacer la buse...