background image

3

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2021 Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

SAFETY INFORMATION (CONT.)

ALWAYS use only the electrical power (voltage and 

frequency) specified on the model plate of the heater.

ALWAYS use only three-prong, grounded outlet and 

extension cord. 
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.  
ALWAYS install the heater so that it is not directly 

exposed to water spray, rain, dripping water, or wind.
NEVER use fuels such as gasoline, benzine, paint 

thinners or other oil compounds in this heater.
NEVER refill the heater’s fuel tank while the heater 

is operating or still hot. This heater is EXTREMELY 

HOT while in operation. 
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.

NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.

Keep all combustible materials away from this heater. 

Minimum Clearance From Combustibles

45-175T-KFA

215T-KFA

Top

4 ft. (122 cm)

4 ft. (122 cm)

Sides

4 ft. (122 cm)

4 ft. (122 cm)

Front

8 ft. (244 cm)

10 ft. (305 cm)

ALWAYS locate heater on a stable and level surface. 
If your heater is equipped with a thermostat, once it 

is plugged in, it can start at anytime in accordance 

with the thermostat setting. 

RISK OF BURNS, 

FIRE AND 

EXPLOSION!

RISK OF ELECTRIC 

SHOCK!

WARNING

WARNING

CAUTION! HOT 

WHILE IN OPERA-

TION. DO NOT 

TOUCH. KEEP CHILDREN, ANIMALS, 

CLOTHING AND COMBUSTIBLES AWAY 

FROM HEATER. 

WARNING

The products described in this manual are 

kerosene direct-fired, forced air heaters. Kerosene 

forced air heaters are primarily intended for use for 

temporary heating of buildings under construction, 

alteration or repair. Direct-fired means that all 

of the combustion products of the heater enter 

the heated space. This appliance is rated at 98% 

combustion efficiency, but does produce small 

amounts of carbon monoxide.

Carbon monoxide is toxic. Humans can tolerate 

only small amounts of carbon monoxide and so 

precautions should be taken to provide proper 

ventilation. Failure to provide proper ventilation 

in accordance with the instructions in this manual 

can result in death. People with breathing 

problems should consult a physician before 

using this heater. Early signs of carbon monoxide 

poisoning resemble the flu. Symptoms of improper 

ventilation/carbon monoxide poisoning are:

Headache 

• 

Dizziness 

 Nausea 

• 

Dry Mouth 

Sore 

Throat 

 Burning of Nose and Eyes

If you experience any of these symptoms: 

GET FRESH AIR AT ONCE! Have your heater 

serviced and check for proper ventilation. Some 

people are more affected by carbon monoxide 

than others. These include: pregnant women, those 

with heart or lung problems, anemia or those under 

the influence of alcohol or at high altitudes. 
FOR OUTDOOR USE. INDOOR USE PERMITTED 

ONLY FOR: The temporary heating of adequately 

ventilated buildings or structures under 

construction, alteration or repair. Provide at 

least a three square foot (2,800 sq cm) opening 

of outside air for every 100,000 Btu/Hr (29 kW) 

heater rating. Refer to “Ventilation” on page 6 for 

further instructions.

RISK OF INDOOR 

AIR POLLUTION!

WARNING

CARBON 

MONOXIDE 

POISONING MAY 

LEAD TO DEATH!

DANGER

Содержание REMINGTON REM-140T-KFA-B

Страница 1: ...N THIS HEATER IS SUITABLE FOR OUTDOOR USE AND INDOOR USE ONLY IN WELL VENTILATED AREAS INDOOR USE PERMITTED ONLY FOR THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTR...

Страница 2: ...ED DO NOT START THE HEATER WHEN THE CHAMBER IS HOT WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from t...

Страница 3: ...D COMBUSTIBLES AWAY FROM HEATER WARNING The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heat...

Страница 4: ...ging materials from the shipping carton Note Save the box and packaging materials for future storage Shown With Optional Cord Wraps Cord Wraps Optional Carry Handle 1 10 mm Screws 2 15 mm Screws 2 WHA...

Страница 5: ...secure before operating the heater SPECIFICATIONS Model 45 KFA 80T KFA 140T KFA 175T KFA 215T KFA Rating Btu Hr kW 45 000 13 2 80 000 23 4 140 000 41 175 000 51 3 215 000 63 Fuel Consumption Gal Hr L...

Страница 6: ...ight or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene shoul...

Страница 7: ...o not have a room temperature display feature The room temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F...

Страница 8: ...re starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fu...

Страница 9: ...rating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 0 21 BAR 80T KFA 4 2 PSI 0 29 BAR...

Страница 10: ...2021 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual WIRING DIAGRAMS 80T KFA 140T KFA 175T KFA 190T KFA 215T KFA Models 140T 175T 190T 215T KFA have a digital display 80T K...

Страница 11: ...mproper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh keros...

Страница 12: ...A POWER SOURCE 2021 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual EXPLODED VIEW 45 KFA 80T KFA Only 140T KFA 215T KFA Only 13 10 12 8 11 9 29 25 3 15 2 4 6 1 7 21 23 16 17...

Страница 13: ...dy 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 18 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020 010...

Страница 14: ...aid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other exp...

Страница 15: ...e ces instructions devraient utiliser ou entretenir cette chaufferette Pour obtenir plus de renseignements manuel d utilisation tiquettes etc contacter Pinnacle Climate Technologies au 800 641 6996 DA...

Страница 16: ...A CHAUFFER ETTE LORSQUE LA CHAMBRE DE COMBUSTION EST CHAUDE RISQUE D INCENDIE DE BR LURE D INHALATION ET D EXPLOSION Garder les mat riaux combustibles tels que mat riaux de construction papier ou cart...

Страница 17: ...emanuelsontdes chaufferettes feudirectet airpuls aliment esau k ros ne Leschaufferettes airforc auk ros nesont principalementdestin esauchauffagetemporairedes b timentsencoursdeconstruction demodifica...

Страница 18: ...carton Remarque Conserver la bo te et les mat riaux d emballage pour y ranger ult rieurement la chaufferette Illustr avec enrouleurs de cordon en option Enrouleurs de cordon en option Poign e 1 Vis d...

Страница 19: ...5T KFA 215T KFA SP CIFICATIONS Mod les n 45 KFA 80T KFA 140T KFA 175T KFA 215T KFA Classement Btu h kWh 45 000 13 2 80 000 23 4 140 000 41 175 000 51 3 215 000 63 Consommation de carburant L h 1 32 2...

Страница 20: ...t d une source de chaleur NE JAMAIS utiliser du k ros ne entrepos la saison pr c dente pour la saison suivante Le k ros ne se d t riore avec le temps LE VIEUX K ROS NE NE BR LE PAS CORRECTEMENT DANS C...

Страница 21: ...ce L afficheur de temp rature ambiante affiche LO Bas lorsque la temp rature ambiante est inf rieure 18 C HI lev e lorsque la temp rature ambiante est sup rieure 37 C Entre 18 C et 37 C l afficheur in...

Страница 22: ...e carburant doit tre nettoy au moins deux fois par saison de chauffage Nettoyer le filtre en le rin ant dans du k ros ne K 1 propre Nettoyer le filtre imm diatement en cas de carburant contamin FILTRE...

Страница 23: ...fonctionne tourner la vis de r glage de la pompe dans le sens horaire pour augmenter la pression et dans le sens antihoraire pour diminuer la pression Pression correcte de la pompe Num ro de mod le Pr...

Страница 24: ...rique 80T KFA 140T KFA 175T KFA 190T KFA NOIR NOIR CELLULE PHOTO LECTRIQUE NOIR NOIR CAPTEUR DE TEMP RATURE AMBIANTE NOIR NOIR FICHE LECTRIQUE JAUNE BLANC VERT LIMITEUR INTERRUPTEUR D ALIMENTATION 120...

Страница 25: ...Jeu incorrect du rotor 1 Remplir le r servoir de k ros ne neuf 2 V rifier la pression de la pompe 3 Nettoyer remplacer la bougie 4 Nettoyer remplacer le filtre carburant 5 Nettoyer remplacer la buse...

Страница 26: ...E UNE SOURCE DE COMBUSTIBLE 2021 Pinnacle Climate Technologies Inc Manuel de la chaufferette air forc au k ros ne VUE CLAT E 45 KFA 80T KFA seulement 140T KFA 215T KFA seulement 13 10 12 8 11 9 29 25...

Страница 27: ...70 021 0510 70 021 0520 70 021 0520 17 Corps de la pompe 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 18 Trousse de rotor 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19...

Страница 28: ...Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un tat d utilisation normale ou n es...

Отзывы: