Captain-i, Installation Guide
34
LED Keypad Used
K
4
RX-180, RXN-200
-
-
RX-6 / RX-406
-
+
Not Used
+
+
Table 5.
Selecting Keypad Type
5.4.7
System configuration 6 (config 6)
[
[
X6: User code #8 as panic code
PDX User 8=Panic
--- Config 6
Par.
Descr. Settings
P
Panic
“+” Entering User code #8 will send panic alert to the CMS
D
Disable Arm
with fails
“+” The system cannot be armed in case of AC or telephone
failure or low battery
X
Not in use
-
5.4.8
System responses to faults and events
Note:
Response Time:
Time between the moment the system identifies a fault until it
is reported. Each fault has a different time response. Response time zero means
immediate report.
[
: Panic code entered
SPGF Siren
---- Panic Resp
.
Par.
Descr. Settings
S
Siren
“+” The siren is triggered
P
Communication “+” The system will dial and/or send radio transmission to
the Monitoring Station and the private account (if
programmed.)
G
PGM
“+” PGM output is triggered
F
Fire
“+” Smoke output is triggered
[
: AC failure
SPBG Siren
---- AC fail
Par.
Descr. Settings
S
Siren
“+” The siren is triggered
P
Communication “+” The system will dial and/or send radio transmission to
the CMS and the private account
B
Buzzer
“+” keypad buzzer activated
G
PGM
“+” PGM output is triggered
[
: Enter AC failure response time in minutes
[
: Battery failure
SPBG Siren
---- Bat fail