Captain-i Installation Guide
35
Par.
Descr. Settings
S
Siren
“+” The siren is triggered
P
Communication “+” The system will dial and/or send radio
transmission to the CMS and the private account.
B
Buzzer
“+” keypad buzzer activated
G
PGM
“+” PGM output is triggered
[
: Telephone line failure
SPBG Siren
---- Phn.fail
Par.
Descr. Settings
S
Siren
“+” The siren is triggered
P
Communication “+” The system will dial and/or send radio transmission
to the Monitoring Station and the private account (if
programmed.)
B
Buzzer
“+” keypad buzzer activated
G
PGM
“+” PGM output is triggered
[
: Enter Telephone line response time in minutes.
[
: Zone failure (for EOL protected zones)
SPBG Siren
---- Zon.fail
Par.
Descr. Settings
S
Siren
“+” The siren is triggered
P
Communication “+” The system will dial and/or send radio transmission
to the Monitoring Station and the private account
B
Buzzer
“+” keypad buzzer activated
G
PGM
“+” PGM output is triggered
[
: Arming/Disarming with a key
STPG Siren check
---- Key stat
Par.
Descr. Settings
S
Siren
“+” The siren beeps to indicate arming/disarming with a key
T
Report
by Radio
“+” Report to CMS by radio
P
Report
by Phone
“+” Report to CMS by phone
G
PGM
“+” PGM output is triggered
5.4.9
Setting entry delay time
[
, the display will show: “Delay times",
[
and the display will show:
"Ent. Delay time:” enter the required delay time in seconds (up to 250 seconds)