Captain-i Installation Guide
29
After setting “Telephone 4,” the display will show “Pre Number.” The installer may
program one or more digits to be dialed before all the above four Monitoring Station
telephone numbers. Programming this screen increases the number of digits available
for the Monitoring Station telephone numbers from 16 to 22. This option should be
used when the system will be dialing the Monitoring Station via a local service provider
who requires the use of pre-dialing digits.
Set “Pre Number” and
[
5.3.4
Setting telephone line characteristics
Program in this screen the number of rings is designed for remote programming with
COMAX via telephone line. In general, the number of rings should be left at its default
setting (10 rings).
[
[
, the display will show "Phone Line:"
[
, enter the number
of rings and
[
5.4
Programming System Characteristics
5.4.1
Setting siren and smoke output parameters
Set the following in this screen:
♦
The duration (in seconds) of the siren alarm time
♦
The length of time that SMOKE output will disconnect the (-) [0 = 60 seconds]
♦
The type of siren tone which will sign (There is a choice of 10 types: 0-9)
Note: Sound type 9 should be chosen only when a self-drive siren is being used (in
which case, it is also necessary to move Jumper JP1 to the left side, see page 13).
[
, the display will show “Siren & Smoke”
[
enter the duration (in
seconds) of the alarm
[
the display will show “Smoke time (sec)”, enter the
time (in seconds)
[
, the display will show “Alarm tones:”; enter the number
[
5.4.2
System configuration 1 (config 1)
[
, the display will show “System config.:”
[
PPTPTB Phone
+----+ Config 1