Captain-i Installation Guide
41
♦
Format is compatible with the one used in the Monitoring Station
♦
Correct dial method, i.e. pulse or tone
♦
Correct telephone numbers have been entered
♦
A prefix (usually 9) is programmed if the system works through a switchboard
No radio transmission to Monitoring Station
Check the following:
♦
Proper connection from the Captain-i PCB to the transmitter
♦
Radio Customer ID is not 0
♦
Station radio ID corresponds to the Monitoring Station
♦
Format is compatible with the one used in the Monitoring Station
No telephone connection to private telephone numbers
Check the following:
♦
The telephone line is properly connected to the IN inputs on the terminal
block
♦
In “Config 1” the P for telephone is programmed with “
+
”
♦
At least one telephone number is programmed for private numbers
♦
Correct telephone numbers have been entered
♦
Correct dial method (pulse or tone)
♦
A prefix (usually 9) is programmed if the system works through a switchboard
System is not answering telephone calls
Check the following:
♦
The telephone line is properly connected to the IN inputs on the terminal block
♦
In “Config 1” the P for telephone is programmed with “
+
”
♦
The system is programmed to pick up after a reasonable number of rings –
Not more than 10
Automatic arming is not functioning
Check the following:
♦
Clock fault (clock is set to the correct time)
♦
The Automatic arming feature is activated. See user’s manual.
Activation of a zone does not cause an alarm
Check the following:
♦
The Zone is not temporarily or permanently bypassed
♦
The zone is programmed for the correct response (siren, relay, etc.)
♦
Power supply is not low – AC or correct battery backup power supply
♦
Detectors are installed correctly and not malfunctioning
Содержание CAPTAIN-i 4410061
Страница 52: ...Captain i Installation Guide 52...