OPERATING MANUAL
PSEN op2H-A series
6.1 Reset to factory configuration
The user has the option to re-establish the light curtain’s factory configuration by operating
the pushbuttons as described below:
1. Press the CONFIRM button and keep it held down for at least 9 s (but not more than
30 s, so that the light curtain is not blocked)
2. The LEDs flash briefly, indicating that the light curtain has been reset to the factory
configuration
3. After the reset has occurred, the light curtain resumes its normal operation with the
factory configuration.
NOTE: Restoring the factory settings will delete the BCM configuration.
6.2 Function list
NOTE: The table highlights the default configuration in bold.
Legend for LED display in RX/TX function list
LED off, LED is not relevant for the information in the “Function” column
LED off, LED is relevant for the information in the “Function” column
LED yellow, value in the “Setting” column is valid for the information in the
“Function” column
LED red, value in the “Setting” column is valid for the information in the “Function”
column
LED green, value in the “Setting” column is valid for the information in the
“Function” column
List of RX functions in muting mode
(LED 3 lights up yellow)
Function
LED
No.
Setting
LED status
P
W
R
O
S
S
D
E
DM
A
CM
LEVEL
Partial Muting
2
3
See the following table
EDM
4
Activated
Deactivated
Restart mode
5
Auto
Manual
Muting direction
6
T (bidirectional)
L (one-directional)
Muting timeout
7
10 min
Infinite
Activation of
override
8
Level
Edge
1003069-EN-03
33