OPERATING MANUAL
PSEN op2H-A series
Fig. 24 – Incorrect OSSD signal load connection
(II)
Fig. 25 – Incorrect OSSD signal load
connection (III)
NOTE: The OSSDs are pulsed. The following diagram shows the time
characteristic of the OSSDs.
115 µs
500 ms
1000 ms
OSSD in safe state
OSSD2
OSSD1
24 V DC
GND
24 V DC
GND
Fig. 26 – Time characteristic of the OSSDs
NO
NO
1003069-EN-03
29