background image

PSEN ma1.4a-52

Operating Manual PSEN ma1.4a-52
22122-EN-06

19

Technical details

General

506321

506323

Approvals

CE, EAC (Eurasian), TÜV, cULus

Listed

CE, EAC (Eurasian), TÜV, cULus

Listed

Sensor's mode of operation

Magnetic

Magnetic

Coding level in accordance with EN

ISO 14119

Low

Low

Design in accordance with EN ISO

14119

4

4

Classification in accordance with

EN 60947-5-3

PDDB

PDDB

Electrical data

506321

506323

Supply voltage

Voltage

24 V

24 V

Kind

DC

DC

Voltage tolerance

-20 %/+20 %

-20 %/+20 %

Supply voltage

Max. current

200 mA

200 mA

Max. switching frequency

1 Hz

1 Hz

Lowest operating current (Im)

1 mA

1 mA

Switching voltage

24 V

24 V

Internal resistance

0 Ohm

0 Ohm

Max. switching current, safety con-

tacts

0,2 A

0,2 A

Max. breaking capacity, safety con-

tacts

5 W

5 W

Times

506321

506323

Reaction time (actuator removed)

2 ms

2 ms

Environmental data

506321

506323

Ambient temperature

Temperature range

-10 - 55 °C

-10 - 55 °C

Climatic suitability

In accordance with the standard

IEC 60068-2-30

IEC 60068-2-30

Humidity

93 % r. h. at 40 °C

93 % r. h. at 40 °C

Max. operating height above sea

level

2000 m

2000 m

EMC

EN 60947-5-3

EN 60947-5-3

Vibration

In accordance with the standard

EN 60947-5-2

EN 60947-5-2

Frequency

10 - 55 Hz

10 - 55 Hz

Amplitude

1 mm

1 mm

Shock stress

Acceleration

30g

30g

Duration

11 ms

11 ms

Содержание PSEN ma1.4a-52

Страница 1: ...PSEN ma1 4a 52 Operating Manual 22122 EN 06 PSEN sensor technology...

Страница 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Страница 3: ...ty 6 Disposal 6 For your safety 7 Unit features 7 Function description 7 Block diagram 8 Operating distances 8 Lateral and vertical offset 9 Wiring 10 Pin assignment 10 Requirements and connection to...

Страница 4: ...particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive...

Страница 5: ...s connections and it must only be op erated with the following components Actuator PSEN ma1 4 03 or actuator PSEN ma1 4 10 interface PSEN ix1 see Order reference 21 and an approved evaluation device T...

Страница 6: ...vices systems and machines the person has to be informed of the state of the art and the applicable national European and international laws directives and standards It is the company s responsibility...

Страница 7: ...ma1 4 10 belongs to the safety switch Coded actuator Safety switch with cable 5 m 2 safety contacts reed contacts N O Different operating distances depending on the actuator see Technical details 19 D...

Страница 8: ...3 4 Actuator Safety switch Magnet Operating distances Sao So Sr Sar mm Somin On Off Legend Sao Assured operating distance Somin Min operating distance Sar Assured release distance The offset independe...

Страница 9: ...Lateral offset 0 1 2 3 4 0 3 0 3 0 2 5 1 5 1 0 1 3 0 2 5 2 0 0 5 2 2 5 1 5 1 0 3 1 5 0 5 4 0 5 The stated values are valid at a temperature of 20 C Actuator PSEN ma1 4 10 Assured operating distance S...

Страница 10: ...voltage Overall cable resistance 15 Ohms per channel On evaluation devices with AC supply voltage Overall cable resistance 25 Ohms per channel For details of how to perform the test for shorts across...

Страница 11: ...PLC for safety gate monitoring with function block FS_SafetyGate The correct connection to the respective evaluation device is described in the operating manual for the evaluation device Make sure th...

Страница 12: ...f the evaluation device s operating manual for the relevant evaluation device Y1 Y8 A2 A1 11 12 14 Y2 Y3 Y4 Y5 Y6 Y9 1 2 3 4 13 23 24 21 22 31 33 34 32 41 43 44 42 A1 A2 1 2 3 4 11 12 14 13 1 2 3 4 21...

Страница 13: ...s must be positioned opposite each other in parallel If possible do not install the safety switch and actuator on to ferromagnetic material Changes to the operating distances are to be expected Safety...

Страница 14: ...stening elements of safety switch and actuator The fastening of safety switch and actuator has to be sufficiently stable to ensure the proper operation of the safety switch and the actuator The distan...

Страница 15: ...r INFORMATION The inscribed area on the actuator sensing face should face the sensor 5 Slide the actuator on to the screws 6 Align sensor and tighten screws with max 0 8 Nm 7 Align actuator and tighte...

Страница 16: ...n for installation type 1 1 Attach the screws for the actuator maintaining the distance between the screw head and the plate ca 3 6 mm 2 Close unused mounting holes on the plate using seal 2 see Diagr...

Страница 17: ...ected evaluation device The stated operating distances see Technical details 19 only apply when the safety switch and actuator are installed according to the specifications Installation 13 Operating d...

Страница 18: ...PSEN ma1 4a 52 Operating Manual PSEN ma1 4a 52 22122 EN 06 18 Dimensions in mm 18 19 8 37 22 4 5 R 8 26 4 14 4 4 5 18 37 22 14 4 18 Safety switch Actuator...

Страница 19: ...requency 1 Hz 1 Hz Lowest operating current Im 1 mA 1 mA Switching voltage 24 V 24 V Internal resistance 0 Ohm 0 Ohm Max switching current safety con tacts 0 2 A 0 2 A Max breaking capacity safety con...

Страница 20: ...2 mm Typical release distance Sr 6 mm 16 mm Repetition accuracy switching distances 6 6 Min distance between safety switches 50 mm 50 mm Sensor flush installation in accord ance with EN 60947 5 2 Yes...

Страница 21: ...with assured operating distance 10 mm 5 m cable 506 323 PSEN ma1 4a 52 1switch Magnetic safety switch 5 m cable 506 303 PSEN ma1 4 03mm 1actuator Actuator with assured operat ing distance 3 mm 506 30...

Страница 22: ...fetyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document d...

Отзывы: