PSEN ma1.4a-52
Operating Manual PSEN ma1.4a-52
22122-EN-06
12
INFORMATION
Risk time in accordance with DIN EN 60947-5-3
The risk time is made up of the reaction time of the sensor (see
Technical
details [
19]
) and the processing and delay times of the evaluation
device (s. operating manual for the relevant evaluation device).
Y1
Y8
A2
A1
11 12
14
Y2 Y3 Y4
Y5 Y6
Y9
1 2 3
4
13
23 24
21 22 31
33 34
32 41
43 44
42
A1
A2
1 2 3 4
11 12
14
13
1 2 3 4
21 22
24
23
1 2 3 4
31
33 34
32
1 2 3 4
41
43 44
42
+24 V
I0.0
I0.1
I0.2
I0.3
+24 V
0 V
PSEN ix1
PLC
PSENmag
Evaluation
device
Input circuit
Input circuit
Fig.: Dual-channel connection of four PSENmag to the input circuits of an evaluation device