PSEN cs5.13 M12/8 EX
Operating Manual PSEN cs5.13 M12/8 EX
22218-EN-04
| 6
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The safety switch is approved for use in potentially explosive atmospheres in accordance
with EN 60079‑0, EN 60079‑7, EN 60079‑18, EN 60079‑31.
Ex area Group II, Category 3G, Zone 2 (Gas): II 3G Ex ec mc IIC T6 Gc and Category 3D,
Zone 22 (dust): II 3D Ex mc tc IIIC T80 °C Dc.
The safety functions of the safety switch are:
}
Safe shutdown of safety outputs when the actuator is removed beyond the assured re-
lease distance s
ar
or when the actuator is not detected
}
Remain shut down safely after the actuator has been removed
The safety switch meets the requirements in accordance with:
}
EN 60947-5-3: PDDB with the actuator PSEN cs5.13 M12 ATEX
}
EN 62061: SIL CL 3
}
EN ISO 13849-1: PL e (Cat. 4)
}
EN ISO 14119: Coding level Low, type 4
The safety switch may only be used with the corresponding actuator PSEN cs5.13 M12
ATEX.
The safety level PL e (Cat. 4)/SIL CL 3 is only achieved if
}
the safety outputs use 2-channel processing.
The actuator may
not
be used in environments with high electromagnetic fields with effect-
ive values > 1 A/m or 3 V/m (e.g. high power electrolysis plants).
The safety switch is suitable for use with a low risk mechanical hazard.
The following is deemed improper use in particular
}
Any component, technical or electrical modification to the product,
}
Use of the product outside the areas described in this manual,
}
Use of the product outside the technical details (see
).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.