PSEN cs5.13 M12/8 EX
Operating Manual PSEN cs5.13 M12/8 EX
22218-EN-04
| 25
DANGER!
Risk of damage due to mechanical load. Live components on the
safety switch in the potentially explosive area may become exposed
Protect the plug-in connector on the safety switch from shock (e.g by using
the PSEN cs1/2 bracket cable fix, see
Please note the information provided under "Installation".
}
Make sure that the earthing is in accordance with the specifications in EN 60079-14.
}
Any metallic parts (also accessories) must be connected to the equipotential bonding in
case of a risk of charging.
CAUTION!
Potential loss of safety function due to changed device properties
The unit's properties may be affected if installed in an environment contain-
ing electrically or magnetically conductive material.
– Please check the operating distances and the assured release dis-
tance.
}
The safety switch and actuator should be installed opposite each other in parallel.
Make sure that the actuator is aligned to the marking on the sensor that guarantees the
operating distance required by the plant design (see
}
Safety switches and actuators should only be secured using M4 screws with a flat head
(e.g. M4 cheese-head or pan head screws).
}
Torque setting: Please note the information provided under
}
The distance between two safety switches must be maintained (see
).
The distance can be undershot in certain application cases (see diagrams).
DEVICE
INPUT
SAFETY GATE
230
DEVICE
INPUT
SAFETY GATE
60
150
DEVICE
INPUT
SAFETY
GA
T
E
95
}
If using angled connector plugs, note the defined angle of the cable routing.
}
When installing make sure you comply with the requirements of EN ISO 14119.