PSEN cs5.13 M12/8 EX
Operating Manual PSEN cs5.13 M12/8 EX
22218-EN-04
| 28
[7]
[1]
[2]
[3]
[6]
[9]
[10]
[10]
[5]
8
4
0
-4
-8
-12
-16
-20
-24
-28
12 8 4 0
8
4
0
-4
-8
-12
-16
-20
-24
-28
[5]
12
8
4
0
9,5
9,5
8
8
[8]
[4]
9,5
9,5
[11]
[12]
[4]
-6,4
-6,4
[1]: Hysteresis
[2]: Typical operating distance
S
O
[3]: Typical release distance S
r
[4]: Offset in mm
[5]: Operating distance in mm
[6]: Response range
[7]: Connector on the sensor
[8] Limit of response range, pos-
ition of gate end stop
[9]: Status of LED
[10]: Sensing face of the actu-
ator, labelled with Pilz logo
Procedure:
1. Drill holes (for M4 screws) in the mounting surface to secure the actuator and sensor
(see
).
2. Use a screw to fix the sensor to the mounting surface.
Make sure that the sensor marking that is be used for operation can be operated using
the actuator from the right side.
3. Do not fully tighten the second screw on the safety switch.
4. Use a screw to fix the actuator to the mounting surface.
Make sure that the actuator with the marking (triangle) points towards the marking on
the sensor.
5. Do not fully tighten the second screw on the actuator.
6. Align the safety switch and tighten the screws.
7. Align the actuator and tighten the screws.
Periodic test
}
Make sure that the work is
not
performed in an explosive atmosphere.
}
Carry out a monthly function test on the safety switch and actuator.
}
Always test the function with a connected evaluation device.
}
The safety function may only be checked by qualified personnel.
}
Refer to the notes on checking the safety switch in EN 60079‑17 and EN 60079‑19.
Adjustment
}
The stated operating distances (see
) only apply when the
safety switch and actuator are installed facing each other in parallel. Operating distances
may deviate if other arrangements are used.
}
Note the maximum permitted lateral and vertical offset (see
and